Improving allowed outage time and surveillance test interval requirements: a study of their interactions using probabilistic methods

Technical Specifications (TS) define the limits and conditions for operating nuclear plants safely. We selected the Limiting Conditions for Operations (LCO) and Surveillance Requirements (SR), both within TS, as the main items to be evaluated using probabilistic methods. In particular, we focused on the Allowed Outage Time (AOT) and Surveillance Test Interval (STI) requirements in LCO and SR, respectively. Already, significant operating and design experience has accumulated revealing several problems which require modifications in some TS rules. Developments in Probabilistic Safety Assessment (PSA) allow the evaluation of effects due to such modifications in AOT and STI from a risk point of view. Thus, some changes have already been adopted in some plants. However, the combined effect of several changes in AOT and STI, i.e. through their interactions, is not addressed. This paper presents a methodology which encompasses, along with the definition of AOT and STI interactions, the quantification of interactions in terms of risk using PSA methods, an approach for evaluating simultaneous AOT and STI modifications, and an assessment of strategies for giving flexibility to plant operation through simultaneous changes on AOT and STI using trade-off-based risk criteria.