Systemic venous circulation. Waves propagating on a windkessel: relation of arterial and venous windkessels to systemic vascular resistance.

Compared with arterial hemodynamics, there has been relatively little study of venous hemodynamics. We propose that the venous system behaves just like the arterial system: waves propagate on a time-varying reservoir, the windkessel, which functions as the reverse of the arterial windkessel. During later diastole, pressure increases exponentially to approach an asymptotic value as inflow continues in the absence of outflow. Our study in eight open-chest dogs showed that windkessel-related arterial resistance was approximately 62% of total systemic vascular resistance, whereas windkessel-related venous resistance was only approximately 7%. Total venous compliance was found to be 21 times larger than arterial compliance (n = 3). Inferior vena caval compliance (0.32 +/- 0.015 ml x mmHg(-1) x kg(-1); mean +/- SE) was approximately 14 times the aortic compliance (0.023 +/- 0.002 ml x mmHg(-1) x kg(-1); n = 8). Despite greater venous compliance, the variation in venous windkessel volume (i.e., compliance x windkessel pulse pressure; 7.8 +/- 1.1 ml) was only approximately 32% of the variation in aortic windkessel volume (24.3 +/- 2.9 ml) because of the larger arterial pressure variation. In addition, and contrary to previous understanding, waves generated by the right heart propagated upstream as far as the femoral vein, but excellent proportionality between the excess pressure and venous outflow suggests that no reflected waves returned to the right atrium. Thus the venous windkessel model not only successfully accounts for variations in the venous pressure and flow waveforms but also, in combination with the arterial windkessel, provides a coherent view of the systemic circulation.

[1]  I. Shrier,et al.  Response of arterial resistance and critical pressure to changes in perfusion pressure in canine hindlimb. , 1993, The American journal of physiology.

[2]  M. N. Levy The Cardiac and Vascular Factors That Determine Systemic Blood Flow , 1979, Circulation research.

[3]  Y. Chen,et al.  Flow through a collapsible tube. Experimental analysis and mathematical model. , 1969, Biophysical journal.

[4]  R. Riley,et al.  Effect of Epinephrine on Pressure, Flow, and Volume Relationships in the Systemic Circulation of Dogs , 1974, Circulation research.

[5]  J. Tyberg Venous modulation of ventricular preload. , 1992, American heart journal.

[6]  K P Brin,et al.  Estimation of total arterial compliance: an improved method and evaluation of current methods. , 1986, The American journal of physiology.

[7]  A Noordergraaf,et al.  Constructive and destructive addition of forward and reflected arterial pulse waves. , 2001, American journal of physiology. Heart and circulatory physiology.

[8]  Timothy J. Pedley,et al.  Modelling Flow and Oscillations in Collapsible Tubes , 1998 .

[9]  Nigel G Shrive,et al.  Time-domain representation of ventricular-arterial coupling as a windkessel and wave system. , 2003, American journal of physiology. Heart and circulatory physiology.

[10]  R W Gore,et al.  Vascular anatomy and hydrostatic pressure profile in the hamster cheek pouch. , 1986, The American journal of physiology.

[11]  J. Grotberg,et al.  BIOFLUID MECHANICS IN FLEXIBLE TUBES , 2001 .

[12]  J. Duomarco,et al.  Energy and hydraulic gradients along systemic veins. , 1954, The American journal of physiology.

[13]  R. Millard,et al.  Gravitational haemodynamics and oedema prevention in the giraffe , 1987, Nature.

[14]  Arthur C. Guyton,et al.  Circulatory physiology : cardiac output and its regulation , 1965 .

[15]  O. Frank,et al.  Die grundform des arteriellen pulses , 1899 .

[16]  G. A. Brecher History of venous research. , 1969, IEEE transactions on bio-medical engineering.

[17]  C. Rothe,et al.  Mean circulatory filling pressure: its meaning and measurement. , 1993, Journal of applied physiology.

[18]  K Sagawa,et al.  Translation of Otto Frank's paper "Die Grundform des Arteriellen Pulses" Zeitschrift für Biologie 37: 483-526 (1899). , 1990, Journal of molecular and cellular cardiology.

[19]  A. Noordergraaf Circulatory System Dynamics , 1978 .

[20]  W. Rose,et al.  Two-port analysis of systemic venous and arterial impedances. , 1993, The American journal of physiology.

[21]  Abraham Noordergraaf,et al.  Pressure-flow characteristics of collapsible tubes: A reconciliation of seemingly contradictory results , 2006, Annals of Biomedical Engineering.

[22]  L. Boxt McDonald's blood flow in arteries , 1991, CardioVascular and Interventional Radiology.

[23]  Koji Kashihara,et al.  A novel framework of circulatory equilibrium. , 2004, American journal of physiology. Heart and circulatory physiology.

[24]  M. Abu-Yousef,et al.  Pulsatile venous Doppler flow in lower limbs: highly indicative of elevated right atrium pressure. , 1996, AJR. American journal of roentgenology.

[25]  A. Guyton,et al.  Determination of cardiac output by equating venous return curves with cardiac response curves. , 1955, Physiological reviews.

[26]  R. Riley,et al.  Critical closure of pulmonary vessels analyzed in terms of Starling resistor model. , 1968, Journal of applied physiology.

[27]  A. C. Burton On the physical equilibrium of small blood vessels. , 1951, The American journal of physiology.

[28]  A. Selzer Circulatory Physiology—Cardiac Output and Its Regulation ed 2. , 1974 .

[29]  J. P. Holt THE COLLAPSE FACTOR IN THE MEASUREMENT OF VENOUS PRESSURE , 1941 .

[30]  I. Shrier,et al.  Maximal vasodilation does not eliminate the vascular waterfall in the canine hindlimb. , 1995, Journal of applied physiology.