Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics

Purpose The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). Materials and Methods The aneurysm model was of saccular morphology (7 mm dome height, 5 mm cross-section, 3–4 mm neck, 3.5 mm parent artery diameter) and connected to a peristaltic pump delivering a physiological flow (250 mL/min) and pulsation rate (70/min). High-resolution (4 h long) 4D phase contrast flow quantification (4D pc-fq) MRI was used to directly assess the hemodynamics of the model. Dynamic MPI, MRI, and DSA were performed with contrast agent injections (3 mL volume in 3 s) through a proximally placed catheter. Results and Discussion 4D pc-fq measurements showed distinct pulsatile flow velocities (20–80 cm/s) as well as lower flow velocities and a vortex inside the aneurysm. All three dynamic methods (MPI, MRI, and DSA) also showed a clear pulsation pattern as well as delayed contrast agent dynamics within the aneurysm, which is most likely caused by the vortex within the aneurysm. Due to the high temporal resolution of MPI and DSA, it was possible to track the contrast agent bolus through the model and to estimate the average flow velocity (about 60 cm/s), which is in accordance with the 4D pc-fq measurements. Conclusions The ionizing radiation free, 4D high resolution MPI method is a very promising tool for imaging and characterization of hemodynamics in human. It carries the possibility of overcoming certain disadvantages of other modalities like considerably lower temporal resolution of dynamic MRI and limited 2D characteristics of DSA. Furthermore, additive manufacturing is the key for translating powerful pre-clinical techniques into the clinic.

[1]  G. Laub,et al.  3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA , 2008, American Journal of Neuroradiology.

[2]  B Gleich,et al.  Three-dimensional real-time in vivo magnetic particle imaging , 2009, Physics in Medicine and Biology.

[3]  A. Wakhloo,et al.  Neurovascular Modeling: Small-Batch Manufacturing of Silicone Vascular Replicas , 2009, American Journal of Neuroradiology.

[4]  Olivier Brina,et al.  Quantification of arterial flow using digital subtraction angiography. , 2012, Medical physics.

[5]  M C M Rutten,et al.  Complex flow patterns in a real‐size intracranial aneurysm phantom: phase contrast MRI compared with particle image velocimetry and computational fluid dynamics , 2012, NMR in biomedicine.

[6]  Justin J. Konkle,et al.  Magnetic Particle Imaging With Tailored Iron Oxide Nanoparticle Tracers , 2015, IEEE Transactions on Medical Imaging.

[7]  N. Forkert,et al.  Aneurysm Recurrence Volumetry Is More Sensitive than Visual Evaluation of Aneurysm Recurrences , 2016, Clinical Neuroradiology.

[8]  Tobias Knopp,et al.  Local System Matrix Compression for Efficient Reconstruction in Magnetic Particle Imaging , 2015 .

[9]  Woowon Jeong,et al.  Hemodynamics of Cerebral Aneurysms: Computational Analyses of Aneurysm Progress and Treatment , 2012, Comput. Math. Methods Medicine.

[10]  Sebastian Schmitter,et al.  4D Flow MRI , 2018 .

[11]  C. Kerber,et al.  Rapid prototyping to create vascular replicas from CT scan data: Making tools to teach, rehearse, and choose treatment strategies , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[12]  Bernhard Gleich,et al.  Magnetic Particle imaging : Visualization of Instruments for Cardiovascular Intervention 1 , 2012 .

[13]  D. Kallmes,et al.  Risk Factors for Growth of Intracranial Aneurysms: A Systematic Review and Meta-Analysis , 2016, American Journal of Neuroradiology.

[14]  Patrick W. Goodwill,et al.  Magnetic Particle Imaging tracks the long-term fate of in vivo neural cell implants with high image contrast , 2015, Scientific Reports.

[15]  J-H Buhk,et al.  3D Printing of Intracranial Aneurysms Using Fused Deposition Modeling Offers Highly Accurate Replications , 2016, American Journal of Neuroradiology.

[16]  Christof Karmonik,et al.  Three-dimensional printing of anatomically accurate, patient specific intracranial aneurysm models , 2015, Journal of NeuroInterventional Surgery.

[17]  Thorsten M. Buzug,et al.  Artifact free reconstruction with the system matrix approach by overscanning the field-free-point trajectory in magnetic particle imaging , 2016, Physics in medicine and biology.

[18]  K. Lovblad,et al.  A DSA-Based Method Using Contrast-Motion Estimation for the Assessment of the Intra-Aneurysmal Flow Changes Induced by Flow-Diverter Stents , 2013, American Journal of Neuroradiology.

[19]  Tobias Knopp,et al.  Combined Preclinical Magnetic Particle Imaging and Magnetic Resonance Imaging: Initial Results in Mice , 2015, Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren.

[20]  Bernhard Gleich,et al.  Tomographic imaging using the nonlinear response of magnetic particles , 2005, Nature.

[21]  Kenichi Kono,et al.  Preoperative simulations of endovascular treatment for a cerebral aneurysm using a patient-specific vascular silicone model. , 2013, Neurologia medico-chirurgica.