Experimental Evidence of Leaks in Elastic Pipes

Several studies have been carried out in recent decades to establish a relationship between total head and leaks. In literature, the leakage governing equations have been analysed in light of pipe materials, water head, leak dimension or shape. Most of these contributions questioned the classical Torricelli equation, demonstrating through experimental evidence that the classical orifice law can give unsatisfactory results. Nevertheless, starting from the Torricelli equation, other exponential or linear governing equations have been proposed as mathematical models able to reproduce the leakages in water distribution systems (WDSs). To investigate the validity of the proposed governing equations, an experimental campaign was carried out by means of a water distribution network composed of approximately 500 m of polyethylene pipes. The experiments were designed to investigate the effects of leak area and pipe rigidity on discharge. Furthermore, the effect of leak size enlargement with water head was analysed. Finally, the proposed research contributes to the population of a database for estimating the coefficients of head-discharge relationships.

[1]  C.R.I. Clayton,et al.  The effect of pressure on leakage in water distribution systems , 2007 .

[2]  G. La Loggia,et al.  Analysis of the impact of intermittent distribution by modelling the network-filling process , 2011 .

[3]  Silvia Meniconi,et al.  Experimental Evidence of Hysteresis in the Head-Discharge Relationship for a Leak in a Polyethylene Pipe , 2011 .

[4]  Joby Boxall,et al.  Influence of Ground Conditions on Intrusion Flows through Apertures in Distribution Pipes , 2013 .

[5]  Selami Kara,et al.  Implementation of Hydraulic Modelling for Water-Loss Reduction Through Pressure Management , 2012, Water Resources Management.

[6]  Enrique Cabrera,et al.  Leakage Assessment through Water Distribution Network Simulation , 2005 .

[7]  Marco Ferrante,et al.  Experimental Investigation of the Effects of Pipe Material on the Leak Head-Discharge Relationship , 2012 .

[8]  Malcolm Farley,et al.  Losses in Water Distribution Networks: A Practitioners' Guide to Assessment, Monitoring and Control , 2015 .

[9]  Silvia Meniconi,et al.  Leak behaviour in pressurized PVC pipes. , 2013 .

[10]  Thomas M. Walski,et al.  Modeling leakage reduction through pressure control , 2006 .

[11]  J. E. van Zyl,et al.  An experimental investigation into the pressure - leakage relationship of some failed water pipes , 2007 .

[12]  Gabriele Freni,et al.  Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis☆ , 2015 .

[13]  Zoran Kapelan,et al.  A review of methods for leakage management in pipe networks , 2010 .

[14]  C. M. Fontanazza,et al.  A model of the filling process of an intermittent distribution network , 2010 .

[15]  Helena M. Ramos,et al.  An overview of leaks and intrusion for different pipe materials and failures , 2014 .

[16]  J. E. van Zyl,et al.  Predicting the head-leakage slope of cracks in pipes subject to elastic deformations , 2013 .

[17]  J. V. Zyl,et al.  Modeling Elastically Deforming Leaks in Water Distribution Pipes , 2014 .

[18]  H. van Waveren,et al.  Model for Success , 2000 .

[19]  Steven G. Buchberger,et al.  Assessing Intrusion Susceptibility in Distribution Systems , 2002 .

[20]  Gabriele Freni,et al.  Implementation of pressure reduction valves in a dynamic water distribution numerical model to control the inequality in water supply , 2014 .

[21]  Silvia Meniconi,et al.  Local and Global Leak Laws , 2014, Water Resources Management.

[22]  A. M. Cassa,et al.  A numerical investigation into the effect of pressure on holes and cracks in water supply pipes , 2010 .

[23]  Richard Burrows,et al.  An Integrated Model to Evaluate Losses in Water Distribution Systems , 2009 .

[24]  A. O. Lambert,et al.  International Report: Water losses management and techniques , 2002 .

[25]  J. V. Zyl,et al.  Experimental Investigation of Internal Fluidisation Due to a Vertical Water Leak Jet in a Uniform Medium , 2015 .

[26]  Jakobus E. van Zyl,et al.  Soil fluidisation outside leaks in water distribution pipes – preliminary observations , 2013 .