DETECTION OF SHORT TRANSIENTS AND INTERRUPTIONS USING THE HILBERT TRANSFORM

In electrical energy power networks, disturbances can cause problems in electronic devices so their monitoring is fundamental in Power Quality. In this paper we address the problem of disturbances estimation by using the Hilbert Transform (HT). It is employed as an effective technique for tracking the voltage waveforms in electrical distribution systems. The mathematical simplicity of the proposed technique, compared with the commonly used algorithms from the literature, renders them competitive candidate for the on-line tracking of disturbances. The accurate tracking of the HT facilitates its implementation for the control of disturbances mitigation devices. Simulation results are provided to verify the tracking capabilities of the algorithm and this has been tested under different conditions: voltage dip with phase jump, noise and frequency changes shows that the Hilbert Transform can be used as a valid methodology for this type

[1]  H. Wayne Beaty,et al.  Electrical Power Systems Quality , 1995 .

[2]  G. L. Goedde,et al.  Surge arrester characteristics that provide reliable overvoltage protection in distribution and low-voltage systems , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[3]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[4]  Fabio Leccese The Perceived Power Quality Way as New Frontiers of Relationship between Customers and Producers , 2008 .

[5]  Fabio Leccese A first analysis of Perceived Power Quality for domestic customers , 2008 .

[6]  Roger C. Dugan,et al.  Operating conflicts for distributed generation on distribution systems , 2001, 2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214).

[7]  A. W. M. van den Enden,et al.  Discrete Time Signal Processing , 1989 .

[8]  Keh-Shew Lu,et al.  DIGITAL FILTER DESIGN , 1973 .

[9]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[10]  Neville R. Watson,et al.  Power System Quality Assessment , 2000 .

[11]  F. Leccese,et al.  Power quality measurements in telecommunication exchanges , 2008, INTELEC 2008 - 2008 IEEE 30th International Telecommunications Energy Conference.

[12]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[13]  Walter G. Scott,et al.  Distributed Power Generation Planning and Evaluation , 2000 .

[14]  Fabio Leccese Analysis of Power Quality Data on some Telecommunication Sites in Rome , 2008 .

[15]  R. C. Dugan,et al.  Impact of induction furnace interharmonics on distribution systems , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[16]  Ieee Standards Board IEEE recommended practice on surge voltages in low-voltage AC power circuits , 1991 .