Automatic Spike Removal Algorithm for Raman Spectra

Raman spectroscopy is a powerful technique, widely used in both academia and industry. In part, the technique’s extensive use stems from its ability to uniquely identify and image various material parameters: composition, strain, temperature, lattice/excitation symmetry, and magnetism in bulk, nano, solid, and organic materials. However, in nanomaterials and samples with low thermal conductivity, these measurements require long acquisition times. On the other hand, charge-coupled device (CCD) detectors used in Raman microscopes are vulnerable to cosmic rays. As a result, many spurious spikes occur in the measured spectra, which can distort the result or require the spectra to be ignored. In this paper, we outline a new method that significantly improves upon existing algorithms for removing these spikes. Specifically, we employ wavelet transform and data clustering in a new spike-removal algorithm. This algorithm results in spike-free spectra with negligible spectral distortion. The reduced dependence on the selection of wavelets and intuitive wavelet coefficient adjustment strategy enables non-experts to employ these powerful spectra-filtering techniques.

[1]  J. Shen,et al.  Stability of exfoliated Bi2Sr2DyxCa1-xCu2O8+δ studied by Raman microscopy , 2010, 1003.1979.

[2]  Inelastic light scattering from correlated electrons , 2006, cond-mat/0607554.

[3]  R. Loudon,et al.  The Raman effect in crystals , 1964 .

[4]  U. Waghmare,et al.  Sharp Raman anomalies and broken adiabaticity at a pressure induced transition from band to topological insulator in Sb2Se3. , 2013, Physical review letters.

[5]  I. R. Lewis,et al.  Handbook of Raman Spectroscopy: From the Research Laboratory to the Process Line , 2001 .

[6]  Daubechies,et al.  Ten Lectures on Wavelets Volume 921 , 1992 .

[7]  R. Merlin,et al.  Raman scattering in materials science , 2000 .

[8]  M. Hsieh,et al.  Alloy effects on the Raman spectra of Si1?xGex and calibration protocols for alloy compositions based on polarization measurements , 2003 .

[9]  Richard L. McCreery,et al.  Raman Spectroscopy for Chemical Analysis , 2000 .

[10]  Reynier I. Revilla,et al.  Autocorrelation Analysis Combined with a Wavelet Transform Method to Detect and Remove Cosmic Rays in a Single Raman Spectrum , 2015, Applied spectroscopy.

[11]  Shuang Jia,et al.  Local phonon mode in thermoelectric Bi2Te2Se from charge neutral antisites , 2016, 1603.00483.

[12]  D. Groom,et al.  Cosmic rays and other nonsense in astronomical CCD imagers , 2002 .

[13]  Stéphane Mallat,et al.  A Theory for Multiresolution Signal Decomposition: The Wavelet Representation , 1989, IEEE Trans. Pattern Anal. Mach. Intell..

[14]  F Ehrentreich,et al.  Spike removal and denoising of Raman spectra by wavelet transform methods. , 2001, Analytical chemistry.

[15]  Yukihiro Ozaki,et al.  Practical Algorithm for Reducing Convex Spike Noises on a Spectrum , 2003, Applied spectroscopy.

[16]  Crystal field splitting in Srn+1IrnO3n+1 (n = 1,2) iridates probed by x-ray Raman spectroscopy , 2014, 1405.6522.

[17]  A. W. M. van den Enden,et al.  Discrete Time Signal Processing , 1989 .

[18]  Anthony T. Tu,et al.  Raman spectroscopy in biology: Principles and applications , 1982 .

[19]  W. Hill,et al.  Spike-correction of weak signals from charge-coupled devices and its application to Raman spectroscopy , 1992 .

[20]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[21]  A. Compaan,et al.  Raman Measurement of Lattice Temperature during Pulsed Laser Heating of Silicon , 1980 .

[22]  Fred H. Pollak,et al.  Raman scattering in alloy semiconductors: Spatial correlation model , 1984 .

[23]  Hyojeong Choi Cosmic-ray interactions in charged-couple devices in the DMTPC 4-shooter detector , 2013 .

[24]  Young-June Kim,et al.  Scattering continuum and possible fractionalized excitations in α-RuCl(3). , 2015, Physical review letters.

[25]  H. Georg Schulze,et al.  A Two-Dimensionally Coincident Second Difference Cosmic Ray Spike Removal Method for the Fully Automated Processing of Raman Spectra , 2014, Applied spectroscopy.

[26]  K. S. Krishnan,et al.  The Raman Effect in Crystals , 1928, Nature.

[27]  S. Cheong,et al.  Raman study of the phonon symmetries in BiFeO 3 single crystals , 2012, 1207.4799.

[28]  A. Kaczor,et al.  Raman spectroscopy of proteins: a review , 2013 .

[29]  Dor Ben-Amotz,et al.  Stripping of Cosmic Spike Spectral Artifacts Using a New Upper-Bound Spectrum Algorithm , 2001 .

[30]  I. Valmianski,et al.  Low vibration high numerical aperture automated variable temperature Raman microscope. , 2016, The Review of scientific instruments.

[31]  Andre K. Geim,et al.  Raman spectrum of graphene and graphene layers. , 2006, Physical review letters.

[32]  Editors , 1986, Brain Research Bulletin.

[34]  Bernhard Schölkopf,et al.  A tutorial on support vector regression , 2004, Stat. Comput..

[35]  Mehmet Fatih Çetin Light scattering in spin orbit coupling dominated systems , 2012 .

[36]  Jun Zhao,et al.  Image Curvature Correction and Cosmic Removal for High-Throughput Dispersive Raman Spectroscopy , 2003, Applied spectroscopy.

[37]  S. Cheong,et al.  Fabrication and characterization of topological insulator Bi2Se3 nanocrystals , 2010, 1008.0396.

[38]  Challa S. S. R. Kumar,et al.  Raman Spectroscopy for Nanomaterials Characterization , 2012 .