Use of the radial groove view intra-operatively to prevent damage to the extensor pollicis longus tendon by protruding screws during volar plating of a distal radial fracture.

The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane. We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.

[1]  H. J. Lee,et al.  Factors affecting late displacement following volar locking plate fixation for distal radial fractures in elderly female patients. , 2013, The bone & joint journal.

[2]  S. White,et al.  Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation , 2012, The Journal of hand surgery, European volume.

[3]  K. Ozer,et al.  Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius. , 2012, The Journal of hand surgery.

[4]  Matthew J. Silva,et al.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. , 2012, The Journal of hand surgery.

[5]  S. Joseph,et al.  The dorsal horizon view: detecting screw protrusion at the distal radius. , 2011, The Journal of hand surgery.

[6]  D. Brown,et al.  Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study. , 2011, Annals of the Royal College of Surgeons of England.

[7]  M. McQueen,et al.  Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes. , 2010, Injury.

[8]  G. Windisch,et al.  Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis , 2009, The Journal of hand surgery, European volume.

[9]  T. Messer,et al.  Complications of Volar Plate Fixation for Managing Distal Radius Fractures , 2009, The Journal of the American Academy of Orthopaedic Surgeons.

[10]  W. Grechenig,et al.  Morphometric analysis of lister's tubercle and its consequences on volar plate fixation of distal radius fractures. , 2008, The Journal of hand surgery.

[11]  C. Martinoli,et al.  Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance. , 2008, AJR. American journal of roentgenology.

[12]  S. Marsico,et al.  Complications of volar plating of distal radius fractures. , 2007, Acta orthopaedica Belgica.

[13]  J. Healy,et al.  Ultrasound Changes in the Extensor Pollicis Longus Tendon Following Fractures of the Distal Radius—A Preliminary Report , 2007, The Journal of hand surgery, European volume.

[14]  Rohit Arora,et al.  Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-Plate , 2007, Journal of orthopaedic trauma.

[15]  P. Evans,et al.  Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study , 2007, Hand.

[16]  M. Al-Rashid,et al.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. , 2006, The Journal of bone and joint surgery. British volume.

[17]  M. Moneim,et al.  Two Potential Causes of EPL Rupture after Distal Radius Volar Plate Fixation , 2006, Clinical orthopaedics and related research.

[18]  D. Zurakowski,et al.  Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. , 2006, The Journal of hand surgery.

[19]  M. Gardner,et al.  Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. , 2006, The Journal of hand surgery.

[20]  A. Faraj,et al.  Dorsal plating for displaced intra-articular fractures of the distal radius. , 2003, Injury.

[21]  R. Letsch,et al.  Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position , 2003, Archives of Orthopaedic and Trauma Surgery.

[22]  J. Jupiter,et al.  Complications following distal radial fractures. , 2001, Instructional course lectures.

[23]  B. Chang,et al.  Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of Internal Fixation. , 2000, Annals of plastic surgery.

[24]  A. Colles On the Fracture of the Carpal Extremity of the Radius , 1814, Edinburgh medical and surgical journal.