The measurement of dyshemoglobins and total hemoglobin by pulse oximetry

Purpose of review Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. Recent findings Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the ratio of oxyhemoglobin to total hemoglobin, displayed as SpO2. Pulse oximeters using up to 12 light wavelengths have recently been developed by Masimo Corp. (Irvine, California, USA). These new ‘Rainbow Pulse CO-oximeter’ instruments can estimate blood levels of carboxyhemoglobin, methemoglobin, and total hemoglobin (SpHb), as well as the conventional SpO2 value. The accuracy of these new measurements has been studied in human volunteers and clinical trials. Some interesting case reports have documented the use of this new technology in diagnosis and treatment. Summary The development of multiwavelength pulse oximeters, which can measure total hemoglobin as well as dyshemoglobins, should result in improved patient care.

[1]  M. Kelner,et al.  Effects of intravenously administered dyes on pulse oximetry readings. , 1986, Anesthesiology.

[2]  K. Tremper,et al.  The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous PO2. , 1987, Anesthesiology.

[3]  S J Barker,et al.  Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. , 1987, Anesthesiology.

[4]  G. Loughlin,et al.  Pulse oximetry is a poor predictor of hypoxemia in stable children with sickle cell disease. , 2000, Archives of pediatrics & adolescent medicine.

[5]  J. Brock‐Utne,et al.  Isosulfan Blue Affects Pulse Oximetry , 2000, Anesthesiology.

[6]  R. Fitzgerald,et al.  Pulse oximetry in sickle cell anemia , 2001, Critical care medicine.

[7]  Katsuyuki Miyasaka,et al.  The theory and applications of pulse spectrophotometry. , 2002, Anesthesia and analgesia.

[8]  S. Wright,et al.  Acquired Methemoglobinemia: A Retrospective Series of 138 Cases at 2 Teaching Hospitals , 2004, Medicine.

[9]  T. Buckley,et al.  Nitrite‐induced methaemoglobinaemia – aetiology, diagnosis and treatment , 2005, Anaesthesia.

[10]  Pulse total-hemoglobinometer provides accurate noninvasive monitoring , 2005, Critical care medicine.

[11]  D. Prough,et al.  Multiwavelength optoacoustic system for noninvasive monitoring of cerebral venous oxygenation: a pilot clinical test in the internal jugular vein. , 2006, Optics letters.

[12]  N. Hampson,et al.  Use of a noninvasive pulse CO-oximeter to measure blood carboxyhemoglobin levels in bingo players. , 2006, Respiratory care.

[13]  S. Barker,et al.  Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study , 2006, Anesthesiology.

[14]  Baruch Ben Dor,et al.  Development and validation of a multiwavelength spatial domain near-infrared oximeter to detect cerebral hypoxia-ischemia. , 2006, Journal of biomedical optics.

[15]  Detecting CO. FDNY studies prehospital assessment of COHb. , 2007, JEMS : a journal of emergency medical services.

[16]  Hemoglobin Bassett produces low pulse oximeter and co-oximeter readings. , 2007, Chest.

[17]  G. Jay,et al.  Carboxyhemoglobin monitored by bedside continuous CO-oximetry. , 2007, The Journal of trauma.

[18]  ROLE OF ANTI-IGE ANTIBODY IN COPD , 2007 .

[19]  Melinda J Throm,et al.  Benzocaine‐Induced Methemoglobinemia in Two Patients: Interdisciplinary Collaboration, Management, and Near Misses , 2007, Pharmacotherapy.

[20]  NONINVASIVE PULSE CO-OXIMETRY AS A TOOL TO DETECT SMOKING STATUS IN AN OUTPATIENT SETTING , 2007 .

[21]  John W. Severinghaus,et al.  History of blood gas analysis. VI. Oximetry , 1986, Journal of Clinical Monitoring.

[22]  L. de Haro,et al.  Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning. , 2008, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[23]  N. Hampson,et al.  Fire and ice: diagnosis of carbon monoxide poisoning in a remote environment , 2008, Emergency Medicine Journal.

[24]  G. Jay,et al.  Non-invasive pulse CO-oximetry screening in the emergency department identifies occult carbon monoxide toxicity. , 2008, The Journal of emergency medicine.