Sensors on instrumented socks for detection of lower leg edema - An in vitro study

This paper presents the design, sensing principles and in vitro evaluation of a novel instrumented sock intended for prediction and prevention of acute decompensated heart failure. The sock contains a drift-free ankle size sensor and a leg tissue elasticity sensor. Both sensors are inexpensive and developed using innovative new sensing ideas. Preliminary tests with the sensor prototypes show promising results: The ankle size sensor is capable of measuring 1 mm changes in ankle diameter and the tissue elasticity sensor can detect 0.15 MPa differences in elasticity. A low-profile instrumented sock prototype with these two sensors has been successfully fabricated and will be evaluated in the future in an IRB-approved human study.

[1]  E. Wolfel,et al.  Can we predict and prevent the onset of acute decompensated heart failure? , 2007, Circulation.

[2]  Jagmeet P. Singh,et al.  Implantable sensors for heart failure. , 2010, Circulation. Arrhythmia and electrophysiology.

[3]  B. Greenberg,et al.  Design of the Multi-Sensor Monitoring in Congestive Heart Failure (MUSIC) study: prospective trial to assess the utility of continuous wireless physiologic monitoring in heart failure. , 2011, Journal of cardiac failure.

[4]  C. Yancy,et al.  Temporal trends in clinical characteristics, treatments, and outcomes for heart failure hospitalizations, 2002 to 2004: findings from Acute Decompensated Heart Failure National Registry (ADHERE). , 2007, American heart journal.

[5]  Kristian Thorlund,et al.  Cardiovascular Events Associated With Smoking Cessation Pharmacotherapies: A Network Meta-Analysis , 2014, Circulation.

[6]  Syed Talha Ali Hamdani,et al.  The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt , 2015, Sensors.

[7]  W. Abraham,et al.  Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure: Prognostic Value of Heart Rate Variability Measured by an Implanted Cardiac Resynchronization Device , 2004, Circulation.

[8]  Peng Peng,et al.  Handheld Microtactile Sensor for Elasticity Measurement , 2011, IEEE Sensors Journal.

[9]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2014 update: a report from the American Heart Association. , 2014, Circulation.

[10]  I. Kiviranta,et al.  In vivo characterization of indentation stiffness of articular cartilage in the normal human knee. , 1999, Journal of biomedical materials research.

[11]  C. O'connor,et al.  Loop Diuretics in Acute Decompensated Heart Failure: Necessary? Evil? A Necessary Evil? , 2009, Circulation. Heart failure.