Unification and Evaluation of the Instantaneous Reactive Power Theories

The instantaneous reactive power (IRP) theory proposed by Akagi and his coauthors is widespread. When applied to a three-phase four-wire system, two types of IRP theories are available: the original and the modified IRP theory. However, there are ambiguities about which is right between the original and the modified theory and what is wrong. In this paper, a unified IRP theory is proposed, in which unequal resistances of transmission lines are taken into account and those ambiguities are clarified. The original IRP theory provides the spatial optimal solution when the neutral line has infinite resistance, and the modified IRP theory when the neutral line has zero resistance. The unified IRP theory proposed in this paper always provides the spatial optimal solution and includes the original and the modified IRP theory.

[1]  Seong-Jeub Jeon,et al.  Definitions of apparent power and power factor in a power system having transmission lines with unequal resistances , 2005 .

[2]  Hirotami Nakano,et al.  Reactive Power Compensation based on An Novel Cross Vector Theory , 1994 .

[3]  Yahia Baghzouz,et al.  Discussion of power definitions contained in the IEEE Dictionary , 1994 .

[4]  L.S. Czarnecki,et al.  On some misinterpretations of the instantaneous reactive power p-q theory , 2004, IEEE Transactions on Power Electronics.

[5]  M. Depenbrock,et al.  Concerning "Instantaneous power compensation in three-phase systems by using p-q-r theory" , 2004, IEEE Transactions on Power Electronics.

[6]  Birgitte Bak-Jensen,et al.  Instantaneous power compensation in three-phase systems by using p-q-r theory , 2002 .

[7]  Jacques L. Willems Discussion of "Generalized theory of instantaneous reactive quantity for multiphase power system" , 2006 .

[8]  A. E. Emanuel Apparent power definitions for three-phase systems , 1999 .

[9]  J. Usaola,et al.  Apparent power and power factor definitions for polyphase non‐linear loads when supply conductors present different resistances , 2007 .

[10]  Jacques L. Willems,et al.  A new interpretation of the Akagi-Nabae power components for nonsinusoidal three-phase situations , 1992 .

[12]  M. Depenbrock The FBD-method, a generally applicable tool for analyzing power relations , 1993 .

[13]  Jacques L. Willems,et al.  Critical analysis of the concepts of instantaneous power current and of active current , 2007 .

[14]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[15]  Robert E. Betz,et al.  Instantaneous power control of induction machines using a novel filtering approach on the back-EMF estimates , 2004 .

[16]  A. E. Emanuel The Buchholz-Goodhue apparent power definition: the practical approach for nonsinusoidal and unbalanced systems , 1998 .

[17]  Optimal standing reserve utilisation using genetic algorithms , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[18]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[19]  Alessandro Ferrero Definitions of electrical quantities commonly used in non-sinusoidal conditions , 2007 .

[20]  Seong-Jeub Jeon Considerations on a reactive power concept in a multiline system , 2006 .

[21]  Seong-Jeub Jeon,et al.  Non-sinusoidal power theory in a power system having transmission lines with frequency-dependent resistances , 2007 .

[22]  Hirofumi Akagi,et al.  The theory of instantaneous power in three-phase four-wire systems: a comprehensive approach , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[23]  M. T. Haque,et al.  A novel control strategy for active filters usable in harmonic polluted and/or imbalanced utility voltage case of 3-phase 4-wire distribution systems , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[24]  Jozef Ghijselen,et al.  The relation between the generalized apparent power and the voltage reference , 2004 .

[25]  P. S. Filipski,et al.  Apparent power: a misleading quantity in the non-sinusoidal power theory: are all non-sinusoidal power theories doomed to fail? , 2007 .

[26]  Aleksandar M. Stankovic,et al.  Frequency-domain observations on definitions of reactive power , 2000 .

[27]  R. Gretsch,et al.  Generalized theory of instantaneous reactive quantity for multiphase power system , 2004, IEEE Transactions on Power Delivery.

[28]  P. Salmeron,et al.  Distorted and unbalanced systems compensation within instantaneous reactive power framework , 2006, IEEE Transactions on Power Delivery.

[29]  A. Sargent,et al.  Cable impedance calculations with parallel circuits and multi-neutral returns in distribution networks , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[30]  M. Depenbrock,et al.  A theoretical investigation of original and modified instantaneous power theory applied to four-wire systems , 2003 .