Volumetric‐modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer

Recently, volumetric‐modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity‐modulated fixed‐field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs‐at‐risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed‐field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient‐specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single‐arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2‐T3 N0‐N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281–601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four‐field (n=4) or five‐field (n=9) step‐and‐shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose‐volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two‐arc plans. The comparison of VMATI with fixed‐field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p=0.47), PTV mean (p=0.12), PTV D95 and PTV V9547.5Gy (95%) (p=0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p=0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p=0.04). VMATI achieved lower lung V20 (p=0.05), whereas lung V5 (p=0.35) and mean lung dose (p=0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p=5.8E−10) and MUs reduced by up to 16% (p=0.001). Integral dose was not statistically different between the two planning techniques (p=0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p=0.76), PTV D95 (p=0.95), mean PTV dose (p=0.78), conformation number (CN) (p=0.26), and MUs (p=0.1). However, the treatment delivery time for VMATII increased significantly by two‐fold (p=3.0E−11) compared to VMATI. VMAT‐based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single‐arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI. PACS number: 87.53.Kn, 87.55.‐x

[1]  E. Hall,et al.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT. , 2003, International journal of radiation oncology, biology, physics.

[2]  E. Dieleman,et al.  Four-dimensional computed tomographic analysis of esophageal mobility during normal respiration. , 2007, International journal of radiation oncology, biology, physics.

[3]  Jian Z. Wang,et al.  Impact of prolonged fraction delivery times on tumor control: a note of caution for intensity-modulated radiation therapy (IMRT). , 2003, International journal of radiation oncology, biology, physics.

[4]  Matthew B Podgorsak,et al.  Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer. , 2011, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[5]  C. Lawton,et al.  The effect of intensity-modulated radiotherapy on radiation-induced second malignancies , 2009 .

[6]  Jeff Z. Y. Chen,et al.  Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  M. Suntharalingam,et al.  Chemoradiotherapy for esophageal cancer. , 2009, Gastrointestinal cancer research : GCR.

[8]  Harald Paganetti,et al.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction , 2008, Physics in medicine and biology.

[9]  Hazim Jaradat,et al.  Integral radiation dose to normal structures with conformal external beam radiation. , 2005, International journal of radiation oncology, biology, physics.

[10]  M. Moerland,et al.  A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. , 1997, International journal of radiation oncology, biology, physics.

[11]  E. Hall,et al.  Intensity-modulated radiation therapy, protons, and the risk of second cancers. , 2006, International journal of radiation oncology, biology, physics.

[12]  Annette Kopp-Schneider,et al.  4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: comparison with a conventional technique using individual margins. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  J. Mechalakos,et al.  IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. , 2009, Medical physics.

[14]  K Paskalev,et al.  Esophageal motion during radiotherapy: quantification and margin implications. , 2010, Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus.

[15]  Suresh Senan,et al.  New developments in arc radiation therapy: a review. , 2010, Cancer treatment reviews.

[16]  A. Koong,et al.  Multimodality treatment with intensity modulated radiation therapy for esophageal cancer. , 2009, Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus.

[17]  Andrzej Niemierko,et al.  Implications of respiratory motion as measured by four-dimensional computed tomography for radiation treatment planning of esophageal cancer. , 2009, International journal of radiation oncology, biology, physics.

[18]  J. Bedford,et al.  Volumetric modulated arc therapy planning for distal oesophageal malignancies. , 2012, The British journal of radiology.

[19]  Radiotherapy for esophageal cancer. , 2005, Journal of clinical gastroenterology.

[20]  Lei Dong,et al.  Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy. , 2004, International journal of radiation oncology, biology, physics.

[21]  M. Kaus,et al.  Development and evaluation of an efficient approach to volumetric arc therapy planning. , 2009, Medical physics.