Differential absorbed dose distributions in lineal energy for neutrons and gamma rays at the mono-energetic neutron calibration facility.

Absorbed dose distributions in lineal energy for neutrons and gamma rays of mono-energetic neutron sources from 140 keV to 15 MeV were measured in the Fast Neutron Laboratory at Tohoku University. By using both a tissue-equivalent plastic walled counter and a graphite-walled low-pressure proportional counter, absorbed dose distributions in lineal energy for neutrons were obtained separately from those for gamma rays. This method needs no knowledge of energy spectra and dose distributions for gamma rays. The gamma-ray contribution in this neutron calibration field >1 MeV neutron was <3%, while for <550 keV it was >40%. The measured neutron absolute absorbed doses per unit neutron fluence agreed with the LA150 evaluated kerma factors. By using this method, absorbed dose distributions in lineal energy for neutrons and gamma rays in an unknown neutron field can be obtained separately.

[1]  A. R. Green,et al.  Assessment of aircrew radiation exposure by further measurements and model development. , 2004, Radiation Protection Dosimetry.

[2]  Takashi S. Nakamura,et al.  Characterisation of a Real-time Personal Neutron Dosemeter with Two Silicon Detectors , 1999 .

[3]  Naohiro Hirakawa,et al.  Development of monoenergetic neutron calibration fields between 8 keV and 15 MeV , 1996 .

[4]  V. Shurshakov,et al.  Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models. , 1996, Radiation measurements.

[5]  H. Schuhmacher,et al.  Operation and Application of Tissue Equivalent Proportional Counters , 1995 .

[6]  H. Menzel,et al.  Measurement of kerma factors for carbon and A-150 plastic: neutron energies from 13.9 to 20.0 MeV , 1992 .

[7]  Y. Shida,et al.  A Data Acquisition System based on a Personal Computer , 1991, Seventh Conference Real Time '91 on Computer Applications in Nuclear, Particle and Plasma Physics Conference Record.

[8]  H. Menzel,et al.  On the Calibration of Tissue-Equivalent Proportional Counters with Built-in Alpha Particle Sources , 1988 .

[9]  A. Waker Experimental uncertainties in microdosimetric measurements and an examination of the performance of three commercially produced proportional counters , 1985 .

[10]  A. Paulsen,et al.  Neutron production cross sections and energies for the reactions 7Li(p,n)7Be and , 1975 .

[11]  Horst Liskien,et al.  Neutron production cross sections and energies for the reactions T(p,n)3He, D(d,n)3He, and T(d,n)4He , 1973 .