Design, Analysis, and Interpretation of Method‐Comparison Studies

Clinicians often need to know whether a new method of measurement is equivalent to an established one already in clinical use. This article reviews the methodology of a method-comparison study to assist the clinician with the conduct and evaluation of such studies. Temperature data from 1 subject are used to illustrate the procedures. Although one would not make decisions on the basis of the findings from 1 subject, the large number of paired measurements in the data set permits its use for illustrative purposes. Currently available software eliminates the need for tedious statistical computation but does not reduce the burden of understanding the concepts underlying a method-comparison study and accurate interpretation of the findings.

[1]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[2]  Maryclare Prasnikar,et al.  Comparison of point-of-care and laboratory glucose analysis in critically ill patients. , 2007, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[3]  L. Critchley,et al.  A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement Techniques , 1999, Journal of Clinical Monitoring and Computing.

[4]  K K Giuliano,et al.  Temperature measurement in critically ill orally intubated adults: a comparison of pulmonary artery core, tympanic, and oral methods. , 1999, Critical care medicine.

[5]  W. Buhre,et al.  Validation of a new arterial pulse contour-based cardiac output device , 2007, Critical care medicine.

[6]  S. Hanneman,et al.  Comparison of methods of temperature measurement in swine , 2004, Laboratory animals.

[7]  Joseph Foss,et al.  Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis , 2000, Anesthesia and analgesia.

[8]  Sheryl Greco,et al.  Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. , 2007, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[9]  L. Mount,et al.  The effects of food intake and fasting on 24-hourly variations in body temperature in the young pig , 2004, Pflügers Archiv.

[10]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[11]  Kiran Hebbar,et al.  Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients , 2005, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[12]  J. Meininger,et al.  Assessing agreement between clinical measurement methods. , 1995, Heart & lung : the journal of critical care.

[13]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[14]  S. Schuh,et al.  Comparison of the Temporal Artery and Rectal Thermometry in Children in the Emergency Department , 2004, Pediatric emergency care.