Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope.

An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ0 = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details.

[1]  Design study of a visible/infrared periscope for intense radiation applications using reflective optics , 1998 .

[2]  B. Peterson,et al.  Calibration and sensitivity of the infrared imaging video bolometer , 2003 .

[3]  Gerhard Raupp,et al.  The compatibility of high confinement times and complete divertor detachment in ASDEX-Upgrade , 1995 .

[4]  B. Peterson,et al.  Calibration of a thin metal foil for infrared imaging video bolometer to estimate the spatial variation of thermal diffusivity using a photo-thermal technique. , 2014, The Review of scientific instruments.

[5]  B. Peterson,et al.  Improved calibration technique of the infrared imaging bolometer using ultraviolet light-emitting diodes. , 2010, The Review of scientific instruments.

[6]  B. Peterson,et al.  Foil Calibration for IR Imaging Bolometer by Laser Irradiation , 2012 .

[7]  G. F. Matthews,et al.  Plasma detachment from divertor targets and limiters , 1995 .

[8]  P. Stangeby,et al.  Experimental divertor physics , 1997 .

[9]  G. Wurden,et al.  The new infrared imaging system on Alcator C-Mod , 1999 .

[10]  R. König,et al.  Optical design study of an infrared visible viewing system for Wendelstein 7-X divertor observation and control. , 2008, The Review of scientific instruments.

[11]  Kim-Hwee Lee First-order optics computation for re-imaging infrared optical systems , 2003, SPIE Defense + Commercial Sensing.

[12]  B. Peterson,et al.  Upgrade of Imaging Bolometers on LHD , 2010 .

[13]  M. Kobayashi,et al.  Control of 3D edge radiation structure with resonant magnetic perturbation fields applied to the stochastic layer and stabilization of radiative divertor plasma in LHD , 2013 .

[14]  E. Gauthier,et al.  ITER-like wide-angle infrared thermography and visible observation diagnostic using reflective optics , 2007 .

[15]  B. Peterson,et al.  Detailed in situ laser calibration of the infrared imaging video bolometer for the JT-60U tokamak , 2006 .

[16]  J. Greivenkamp Field Guide to Geometrical Optics , 2004 .

[17]  A. Sagara,et al.  The large helical device (LHD) helical divertor , 1994 .

[18]  B. Peterson Infrared imaging video bolometer , 2000 .

[19]  Troppmann,et al.  Observation of continuous divertor detachment in H-mode discharges in ASDEX upgrade. , 1995, Physical review letters.

[20]  M. Shoji,et al.  Detachment stabilization with n/m=1/1 resonant magnetic perturbation field applied to the stochastic magnetic boundary of the Large Helical Device , 2010 .