Wideband linear power amplifier for high-frequency ultrasonic coded excitation imaging

Linear power amplifiers are critical components in ultrasonic imaging systems that implement chirp-coded excitation. Bench-top commercial power amplifiers are usually used in academic laboratories for high-frequency ultrasound imaging, and the imaging performance depends greatly on these general-purpose instruments. To achieve a wide dynamic range, a power amplifier consisting of two stages is developed for chirp-coded ultrasound imaging applications through the implementation of custom-designed broadband 1:1 transformers and the optimization of feedback circuits. The amplifier has broad bandwidth (5 to 135 MHz), maintaining a linearity up to the 1-dB gain compression point (P1dB) of 41.5 dBm, allowing 16 dBm input power level at 60 MHz. The mean and the maximum values of output third-order intercept points (OIP3) are 51.8 and 53.5 dBm, respectively, between 20 and 110 MHz. With 12 dBm input power, the gain of the amplifier varies between 24 and 29 dB, offering a uniformity which would allow excitation of a 70-MHz single-element transducer with windowed chirp-coded bursts sweeping from 40 to 100 MHz. The performance in high-frequency ultrasound imaging is evaluated with a wire phantom. Echo signal-to-noise ratio (eSNR) of the designed amplifier is 7 dB better than a commercial amplifier, and spatial resolution is maintained.

[1]  A. Sedra Microelectronic circuits , 1982 .

[2]  J. Mamou,et al.  Chirp-coded excitation imaging with a high-frequency ultrasound annular array , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  R. Y. Chiao,et al.  Coded excitation for diagnostic ultrasound: a system developer's perspective , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  H. Ermert,et al.  A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  J. Sevick Transmission Line Transformers , 1990 .

[6]  Qifa Zhou,et al.  Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging. , 2006, Ultrasonics.

[7]  C. Trask Designing Wide-band Transformers for HF and VHF Power Amplifiers , 2005 .

[8]  M. O'Donnell,et al.  Coded excitation system for improving the penetration of real-time phased-array imaging systems , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Xiaochen Xu,et al.  A low-cost bipolar pulse generator for high-frequency ultrasound applications , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  J.A. Jensen,et al.  Use of modulated excitation signals in medical ultrasound. Part I: basic concepts and expected benefits , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Reuben Lee Electronic transformers and circuits. , 1988 .

[12]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[13]  Pascal Laugier,et al.  Real-time Chirp-Coded Imaging With a Programmable Ultrasound Biomicroscope , 2010, IEEE Transactions on Biomedical Engineering.

[14]  K. Shung,et al.  Diagnostic Ultrasound: Imaging and Blood Flow Measurements , 2005 .

[15]  J. K. Poulsen Low loss wideband protection circuit for high frequency ultrasound , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).