A measurement system and image reconstruction in magnetic induction tomography.

Magnetic induction tomography (MIT) is a technique for imaging the internal conductivity distribution of an object. In MIT current-carrying coils are used to induce eddy currents in the object and the induced voltages are sensed with other coils. From these measurements, the internal conductivity distribution of the object can be reconstructed. In this paper, we introduce a 16-channel MIT measurement system that is capable of parallel readout of 16 receiver channels. The parallel measurements are carried out using high-quality audio sampling devices. Furthermore, approaches for reconstructing MIT images developed for the 16-channel MIT system are introduced. We consider low conductivity applications, conductivity less than 5 S m(-1), and we use a frequency of 10 MHz. In the image reconstruction, we use time-harmonic Maxwell's equation for the electric field. This equation is solved with the finite element method using edge elements and the images are reconstructed using a generalized Tikhonov regularization approach. Both difference and static image reconstruction approaches are considered. Results from simulations and real measurements collected with the Philips 16-channel MIT system are shown.

[1]  Nevzat G. Gencer,et al.  Electrical conductivity imaging via contactless measurements: an experimental study , 2003, IEEE Transactions on Medical Imaging.

[2]  M. Vauhkonen,et al.  Imagereconstruction approaches for Philips magnetic induction tomograph , 2007 .

[3]  H. Griffiths,et al.  A numerical model for magnetic induction tomographic measurements in biological tissues. , 2001, Physiological measurement.

[4]  Hermann Scharfetter,et al.  Spectroscopic 16 channel magnetic induction tomograph: The new Graz MIT system , 2007 .

[5]  J Netz,et al.  Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance. , 1993, Physiological measurement.

[6]  H Scharfetter,et al.  A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration. , 2006, Physiological measurement.

[7]  H Griffiths,et al.  A primary field compensation scheme for planar array magnetic induction tomography. , 2004, Physiological measurement.

[8]  Jian-Ming Jin,et al.  The Finite Element Method in Electromagnetics , 1993 .

[9]  M. Soleimani,et al.  A three-dimensional inverse finite-element method applied to experimental eddy-current imaging data , 2006, IEEE Transactions on Magnetics.

[10]  A Korjenevsky,et al.  Magnetic induction tomography: experimental realization. , 2000, Physiological measurement.

[11]  Claudia Hannelore Igney,et al.  16 Channel Magnetic Induction Tomography System Featuring Parallel Readout , 2007 .

[12]  Hermann Scharfetter,et al.  A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT). , 2005, Physiological measurement.

[13]  O. Bíró Edge element formulations of eddy current problems , 1999 .

[14]  H Griffiths,et al.  Residual capacitive coupling and the measurement of permittivity in magnetic induction tomography , 2007, Physiological measurement.

[15]  Hermann Scharfetter,et al.  Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy). , 2003, Physiological measurement.

[16]  R McFee,et al.  Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction. , 1968, IEEE transactions on bio-medical engineering.

[17]  The development of high frequency electromagnetic inductance tomography for low conductivity materials. , 2002 .

[18]  Steffen Leonhardt,et al.  Development of the Multichannel Simultaneous Magnetic Induction Measurement System Musimitos , 2007 .