Registration of Abdominal CT and SPECT Images Using Compton Scatter Data

The present study investigates the possibility to utilize Compton scatter data for registration of abdominal SPECT images. A method for registration to CT is presented, based on principal component analysis and cross-correlation of binary images representing the interior of the patient. Segmentation of scatter images is performed with two methods, thresholding and a deformable contour method. To achieve similarity of organ positions between scans, a positioning device is applied to the patient. Evaluation of the registration accuracy is performed with a) a 131I phantom study, b) a Monte Carlo simulation study of an anthropomorphic phantom, and c) a 123I patient trial. For a) r.m.s. distances between positions that should be equal in CT and SPECT are obtained to 1.0±0.7 mm, which thus for a rigid object is at sub pixel level. From b) results show that r.m.s. distances depend on the slice activity distribution. With a symmetrical distribution deviations are in the order of 5 mm. In c) distances between markers on the patient boundary are at the maximum 16 mm and on an average 10 mm. It is concluded that by utilizing the available Compton scatter data, valuable positioning information is achieved, that can be used for registration of SPECT images.

[1]  E. Pedroni,et al.  The calibration of CT Hounsfield units for radiotherapy treatment planning. , 1996, Physics in medicine and biology.

[2]  B Maziere,et al.  76Br-MBBG, a PET radiotracer to investigate the norepinephrine neurological and vesicular transproters in the heart. , 1995, Nuclear medicine and biology.

[3]  Rafael C. González,et al.  Local Determination of a Moving Contrast Edge , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  E M Stokely,et al.  Single-photon tomographic study of regional cerebral blood flow after stroke: concise communication. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[6]  M. Ljungberg,et al.  A Monte Carlo program for the simulation of scintillation camera characteristics. , 1989, Computer methods and programs in biomedicine.

[7]  Michael A. King,et al.  Segmentation of the body and lungs from Compton scatter and photopeak window data in SPECT: a Monte-Carlo investigation , 1996, IEEE Trans. Medical Imaging.

[8]  J. F. Bradshaw,et al.  The principal axes transformation--a method for image registration. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  R L Wahl,et al.  CT-SPECT fusion plus conjugate views for determining dosimetry in iodine-131-monoclonal antibody therapy of lymphoma patients. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  E. Yorke,et al.  A new fiducial alignment system to overlay abdominal computed tomography or magnetic resonance anatomical images with radiolabeled antibody single‐photon emission computed tomographic scans , 1994, Cancer.

[11]  C. Pelizzari,et al.  Accurate Three‐Dimensional Registration of CT, PET, and/or MR Images of the Brain , 1989, Journal of computer assisted tomography.

[12]  Ramesh C. Jain,et al.  Using Dynamic Programming for Solving Variational Problems in Vision , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[13]  M. Viergever,et al.  Medical image matching-a review with classification , 1993, IEEE Engineering in Medicine and Biology Magazine.

[14]  D. Weber,et al.  Correlative image registration. , 1994, Seminars in nuclear medicine.

[15]  M E Noz,et al.  CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings. , 1989, Radiology.

[16]  M E Noz,et al.  CT-SPECT fusion for analysis of radiolabeled antibodies: applications in gastrointestinal and lung carcinoma. , 1991, International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology.

[17]  Flux Gd Multimodality image registration and its application to the dosimetry of intralesional radionuclide therapy. , 1995 .

[18]  I. Perkash,et al.  Registration error quantification of a surface-based multimodality image fusion system. , 1995, Medical physics.

[19]  A. Scott,et al.  Image registration of SPECT and CT images using an external fiduciary band and three-dimensional surface fitting in metastatic thyroid cancer. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  I. Kanno,et al.  Automated interstudy image registration technique for SPECT and PET. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.