A Novel Online Technique to Detect Power Transformer Winding Faults

Frequency-response analysis (FRA) has been growing in popularity in recent times as a tool to detect mechanical deformation within power transformers. To conduct the test, the transformer has to be taken out of service which may cause interruption to the electricity grid. Moreover, because FRA relies on graphical analysis, it calls for an expert to analyze the results. As so far, there is no standard code for FRA interpretation worldwide. In this paper, a novel online technique is introduced to detect the internal faults within a power transformer by constructing the voltage-current (V - I) locus diagram to provide a current state of the transformer. The technique does not call for any special equipment as it uses the existing metering devices attached to any power transformer to monitor the input voltage, output voltage, and the input current at the power frequency and, hence, online monitoring can be realized. Various types of faults have been simulated to assess its impact on the proposed locus. A Matlab code based on digital image processing is developed to calculate any deviation of the V - I locus with respect to the reference one and to identify the type of fault. The proposed technique is easy to be implemented and automated so that the requirement for expert personnel can be eliminated.

[1]  Syed Islam Detection of shorted turns and winding movements in large power transformers using frequency response analysis , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[2]  Melcher P. Fobes,et al.  Calculus and analytic geometry , 1963 .

[3]  E.P. Dick,et al.  Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.

[4]  Dean Sharafi Life Extension of a Group of Western Power Transformers , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[5]  J. Bak-Jenson,et al.  Parametric identification in potential transformer modelling , 1992 .

[6]  K. Okuyama,et al.  A Calculation Method for Impulse Voltage Distribution and Transferred Voltage in Transformer Windings , 1978, IEEE Transactions on Power Apparatus and Systems.

[7]  E. J. Figueroa MANAGING AN AGING FLEET OF TRANSFORMERS , 2009 .

[8]  Z.D. Wang,et al.  Winding movement in power transformers: a comparison of FRA measurement connection methods , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  Ahmed Abu-Siada,et al.  Frequency Response Analysis Using High Frequency Transformer Model , 2009 .

[10]  J. Pleite,et al.  Power transformer core fault diagnosis using frequency response analysis , 2006, MELECON 2006 - 2006 IEEE Mediterranean Electrotechnical Conference.

[11]  Gerard Ledwich,et al.  Locating transformer faults through sensitivity analysis of high frequency modeling using transfer function approach , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[12]  B. D. Sparling Transformer monitoring moving forward from monitoring to diagnostics , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[13]  E. Billig,et al.  Mechanical stresses in transformer windings , 1946 .

[14]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[15]  Wensheng Gao,et al.  Deformation analysis of transformer winding by structure parameter , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[16]  N. Abeywickrama,et al.  Effect of Core Magnetization on Frequency Response Analysis (FRA) of Power Transformers , 2008, IEEE Transactions on Power Delivery.

[17]  J. P. Reynders,et al.  Failures in power system transformers and appropriate monitoring techniques , 1999 .

[18]  Stefan Tenbohlen,et al.  Experimental and theoretical investigation of disc space variation in real high-voltage windings using transfer function method , 2010 .

[19]  Jiangjun Ruan,et al.  Calculation of parameters in transformer winding based on the model of multi-conductor transmission line , 2008, 2008 International Conference on Electrical Machines and Systems.

[20]  Hormatollah Firoozi,et al.  Transformer Fault Diagnosis Using Frequency Response Analysis - Practical Studies , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[21]  A A Reykherdt,et al.  Case studies of factors influencing frequency response analysis measurements and power transformer diagnostics , 2011, IEEE Electrical Insulation Magazine.