Broad band tunable quantum cascade lasers for stand-off detection of explosives

We present experimental results on a Quantum cascade laser (QC laser) embedded in an external cavity. These results were obtained with a broadly tunable laser exceeding 80 cm-1 covering a characteristic absorption band of trinitrotoluene (TNT). By combining the laser source with a high performance IR imager a stand-off detection setup based on multi- spectral MIR backscattering spectroscopy has been realized. With this technique TNT surface-contaminations of as low as 10 μg/cm2 could be detected on surfaces such as an aluminum-sheet and standard car paint. The contrast of the detection technique depends on the reflectance of the surface. A surface leading to mirror-like reflectance of the IR laser radiation leads to absorbance-like signatures of the TNT contamination, while surfaces showing high absorbance of the laser light may induce a contrast-reversal in the resulting image of the TNT coverage. This effect can be explained by a theoretical model for thin film coated substrates taking into account differences in the reflectance. Limitations and further work needed to explore the full potential of the IR backscattering technique are also discussed.

[1]  Shi-qi Huang,et al.  A novel method for speckle noise reduction and ship target detection in SAR images , 2009, Pattern Recognit..

[2]  Denis Joyeux,et al.  Speckle Removal by a Slowly Moving Diffuser Associated with a Motionless Diffuser , 1971 .

[3]  S. Corzine,et al.  Widely tunable mode-hop free external cavity quantum cascade lasers for high resolution spectroscopy and chemical sensing , 2008 .

[4]  Paul H. Holloway,et al.  Remote Sensing of Explosive Materials Using Differential Reflection Spectroscopy , 2006 .

[5]  Jérôme Faist,et al.  External cavity quantum cascade laser , 2010 .

[6]  Manu Prasanna,et al.  High-sensitivity detection of TNT , 2006, Proceedings of the National Academy of Sciences.

[7]  M. Bashkansky,et al.  Statistics and reduction of speckle in optical coherence tomography. , 2000, Optics letters.

[8]  Victor Yurlov,et al.  Speckle suppression in scanning laser displays: aberration and defocusing of the projection system. , 2009, Applied optics.

[9]  Yargo Bonetti,et al.  External cavity quantum cascade laser tunable from 7.6 to 11.4 μm , 2009 .

[10]  T H Allen,et al.  Comparison of the properties of titanium dioxide films prepared by various techniques. , 1989, Applied optics.

[11]  Mattias Beck,et al.  High-temperature operation of distributed feedback quantum-cascade lasers at 5.3 μm , 2001 .

[12]  Wolfgang Bronner,et al.  Time-resolved characterization of external-cavity quantum-cascade lasers , 2009 .

[13]  A. Pettersson,et al.  Laser-based standoff detection of explosives: a critical review , 2009, Analytical and bioanalytical chemistry.

[14]  C. W. van Neste,et al.  Standoff photoacoustic spectroscopy , 2008 .

[15]  Michael Gaft,et al.  Standoff laser-based spectroscopy for explosives detection , 2007, SPIE Security + Defence.

[16]  Mattias Beck,et al.  Continuous Wave Operation of a Mid-Infrared Semiconductor Laser at Room Temperature , 2001, Science.

[17]  A. K. Sharma,et al.  Potentials and limits of mid-infrared laser spectroscopy for the detection of explosives , 2008 .

[18]  David Chapman,et al.  Widely tunable single-mode quantum cascade laser source for mid-infrared spectroscopy , 2007 .

[19]  Manu Prasanna,et al.  High-sensitivity detection of triacetone triperoxide (TATP) and its precursor acetone. , 2007, Applied optics.

[20]  W. Bronner,et al.  Spectral tuning and mode competition of quantum cascade lasers studied by time-resolved Fourier transform spectroscopy , 2006, SPIE Optics East.

[21]  Anatoliy Lapchuk,et al.  Speckle suppression in laser display using several partially coherent beams. , 2009, Optics express.

[22]  Federico Capasso,et al.  Widely tunable high-power external cavity quantum cascade laser operating in continuous-wave at room temperature , 2009 .

[23]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[24]  Chris Dyer,et al.  Short-range remote detection of liquid surface contamination by active imaging Fourier transform spectrometry. , 2008, Optics express.

[25]  R. A. McGill,et al.  Stand-off detection of trace explosives via resonant infrared photothermal imaging , 2008 .

[26]  Plamen A Demirev,et al.  Arrayed time-of-flight mass spectrometry for time-critical detection of hazardous agents. , 2005, Analytical chemistry.

[27]  W. Bronner,et al.  Current- and Temperature-Induced Beam Steering in 7.8-${\mu}$m Emitting Quantum-Cascade Lasers , 2008, IEEE Journal of Quantum Electronics.

[28]  M. Beck,et al.  Far infrared quantum-cascade lasers based on a bound-to-continuum transition , 2001, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[29]  Siegfried R. Waldvogel,et al.  Fiber optic evanescent field sensor for detection of explosives and CO2 dissolved in water , 2008 .