Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

The absence of adequate testing standards for engine-driven nickel-titanium (NiTi) instruments necessitates further study of these instruments in all areas. This study examined three groups of engine-driven rotary NiTi endodontic instruments (Profile, Hero, and Quantec) and assessed the times for dynamic fracture in relation to the radius of curvature to which the instruments were subjected during preparation, with the instrument diameter determined by size and taper and the mode by which the fracture occurred. Ten instruments were randomly selected representing each size and taper for each group and for each radius of curvature: 600 in total. The instruments were rotated at 350 rpm and introduced into a tempered steel curve that simulated a canal. Two radii of curvature of canals were used: 5 and 10 mm. Time at fracture was noted for all files, and the fracture faces of each file were analyzed with scanning electron microscopy. Radius of curvature was found to be the most significant factor in determining the fatigue resistance of the files. As radius of curvature decreased, fracture time decreased. Taper of files was found to be significant in determining fracture time. As diameter increased, fracture time decreased. In all cases, fracture was found to be of a ductile nature, thus implicating cyclic fatigue as a major cause of failure and necessitating further analyses and setting of standards in this area.

[1]  H. Gerstein,et al.  An initial investigation of the bending and torsional properties of Nitinol root canal files. , 1988, Journal of endodontics.

[2]  W J Pertot,et al.  Torsional and stiffness properties of nickel-titanium K files. , 1995, International endodontic journal.

[3]  S B Dove,et al.  A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. , 1995, Journal of endodontics.

[4]  Walton Re,et al.  Instrument deterioration with usage: nickel-titanium versus stainless steel. , 1997 .

[5]  J. P. Pruett,et al.  Cyclic fatigue testing of nickel-titanium endodontic instruments. , 1997, Journal of endodontics.

[6]  J. Camps,et al.  Machining efficiency of nickel-titanium K-type files in a linear motion. , 1995, International endodontic journal.

[7]  E. Schäfer,et al.  Properties of endodontic hand instruments used in rotary motion. Part 3. Resistance to bending and fracture. , 1997, Journal of endodontics.

[8]  W. Brantley,et al.  Bending and metallurgical properties of rotary endodontic instruments. IV. Gates Glidden and Peeso drills. , 1993, Journal of endodontics.

[9]  P. Wilson,et al.  Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. , 1998, Journal of endodontics.

[10]  P. Wilson,et al.  Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. , 1998, Journal of endodontics.

[11]  L. I. Grossman,et al.  Guidelines for the prevention of fracture of root canal instruments. , 1969, Oral surgery, oral medicine, and oral pathology.

[12]  P. Gasser,et al.  Dynamic fracture of hybrid endodontic hand instruments compared with traditional files. , 1991, Journal of endodontics.

[13]  D. Dederich,et al.  The effects of cyclical axial motion on rotary endodontic instrument fatigue. , 1986, Oral surgery, oral medicine, and oral pathology.

[14]  Equipment,et al.  Revised American National Standards Institute/American Dental Association specification no. 28 for root canal files and reamers, type K. Council on Dental Materials, Instruments, and Equipment. , 1982, Journal of the American Dental Association.

[15]  J I Nicholls,et al.  Torsional properties of stainless steel and nickel-titanium endodontic files. , 1995, Journal of endodontics.

[16]  J Camps,et al.  Torsional and stiffness properties of Canal Master U stainless steel and nitinol instruments. , 1994, Journal of endodontics.