Running-specific prostheses permit energy cost similar to nonamputees.

UNLABELLED Improvements in prosthesis design have facilitated participation in competitive running for persons with lower limb loss (AMP). PURPOSE The purpose of this study was to examine the physiological responses of AMP using a run-specific prosthesis (RP) versus a traditional prosthesis (P) and cross-referenced with nonamputee controls (C) matched by training status, age, gender, and body composition during level treadmill running (TM). METHODS Twelve trained runners completed a multistage submaximal TM exercise during which HR and oxygen uptake (VO(2)) were obtained. Steady state measures at 134 m x min(-1) were compared between RP and P in AMP. AMP using RP (AMP-RP) and C also performed a continuous speed-incremented maximal TM test until volitional fatigue. RESULTS RP elicited lower HR and VO(2) compared with P in AMP. Using RP, AMP achieved similar VO(2max) and peak TM speed compared with C but with higher HR(max). Relative HR (%HR(max)) and oxygen uptake (%VO(2max)), the regression intercept, slope, SEE, and Pearson's r correlation were not different between AMP-RP and C. %HR(max) calculated with the published equation, %HR(max) = 0.73(%VO(2max)) + 30, was not significantly different from actual %HR(max) for AMP-RP or C in any stage. CONCLUSIONS RP permits AMP to attain peak TM speed and aerobic capacity similar to trained nonamputees and significantly attenuates HR and energy cost of submaximal running compared with a P. Use of RP confers no physiological advantage compared with nonamputee runners because energy cost at the set speed was not significantly different for AMP-RP. Current equations on the basis of the relative HR-VO(2) relationship seem appropriate to prescribe exercise intensity for persons with transtibial amputations using RP.

[1]  L. M. Sheldahl,et al.  Physiological comparison of walking among bilateral above-knee amputee and able-bodied subjects, and a model to account for the differences in metabolic cost. , 1997, Archives of physical medicine and rehabilitation.

[2]  M. Hopman,et al.  Rapid vascular adaptations to training and detraining in persons with spinal cord injury. , 2006, Archives of physical medicine and rehabilitation.

[3]  J. González-Alonso Point: Stroke volume does/does not decline during exercise at maximal effort in healthy individuals. , 2008, Journal of applied physiology.

[4]  J G Buckley Biomechanical adaptations of transtibial amputee sprinting in athletes using dedicated prostheses. , 2000, Clinical biomechanics.

[5]  Miao-Ju Hsu,et al.  The effects of added prosthetic mass on physiologic responses and stride frequency during multiple speeds of walking in persons with transtibial amputation. , 2003, Archives of physical medicine and rehabilitation.

[6]  J. Keul,et al.  Size and blood flow of central and peripheral arteries in highly trained able-bodied and disabled athletes. , 2003, Journal of applied physiology.

[7]  S. Hooker,et al.  Oxygen uptake and heart rate relationship in persons with spinal cord injury. , 1993, Medicine and science in sports and exercise.

[8]  H J Yack,et al.  Physiological measurements of walking and running in people with transtibial amputations with 3 different prostheses. , 1999, The Journal of orthopaedic and sports physical therapy.

[9]  Giuseppe Lippi,et al.  Pistorius ineligible for the Olympic Games: the right decision , 2008, British Journal of Sports Medicine.

[10]  T. Schoppen,et al.  Development of an exercise testing protocol for patients with a lower limb amputation: results of a pilot study , 2005, International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation.

[11]  M. Nash,et al.  The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees , 1997, Prosthetics and orthotics international.

[12]  Effects of graduated compression stockings on cardiovascular and metabolic responses to exercise and exercise recovery in persons with spinal cord injury. , 2007, Archives of physical medicine and rehabilitation.

[13]  Miao-Ju Hsu,et al.  Physiological Comparisons of Physically Active Persons with Transtibial Amputation Using Static and Dynamic Prostheses versus Persons with Nonpathological Gait during Multiple-Speed Walking , 2000 .

[14]  J. Skinner,et al.  Limits to Maximal Performance in Individuals with Spinal Cord Injury , 1998, International journal of sports medicine.

[15]  Christine Detrembleur,et al.  Relationship between energy cost, gait speed, vertical displacement of centre of body mass and efficiency of pendulum-like mechanism in unilateral amputee gait. , 2005, Gait & posture.

[16]  R. Waters,et al.  Energy cost of walking of amputees: the influence of level of amputation. , 1976, The Journal of bone and joint surgery. American volume.

[17]  M. Meyers,et al.  Exercise Performance of Lower-Extremity Amputees , 1995, Sports medicine.

[18]  The oxygen uptake-heart rate relationship in trained female wheelchair athletes. , 2004, Journal of rehabilitation research and development.

[19]  D. Shurr,et al.  The effects of prosthetic foot design on physiologic measurements, self-selected walking velocity, and physical activity in people with transtibial amputation. , 2006, Archives of physical medicine and rehabilitation.

[20]  T. Schmalz,et al.  Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components. , 2002, Gait & posture.

[21]  A. Lucia,et al.  Stroke volume does/does not decline during exercise at maximal effort in healthy individuals , 2008 .

[22]  M. Nash,et al.  Energy expenditure of trans-tibial amputees during ambulation at self-selected pace , 1994, Prosthetics and orthotics international.

[23]  P. Willems,et al.  Effect of speed on the energy cost of walking in unilateral traumatic lower limb amputees , 2008, European Journal of Applied Physiology.

[24]  P. E. Martin,et al.  Walking symmetry and energy cost in persons with unilateral transtibial amputations: matching prosthetic and intact limb inertial properties. , 2000, Archives of physical medicine and rehabilitation.

[25]  L. Swartz,et al.  Cyborg anxiety: Oscar Pistorius and the boundaries of what it means to be human , 2008 .

[26]  D. Warburton,et al.  Counterpoint: Stroke volume does not decline during exercise at maximal effort in healthy individuals. , 2008, Journal of applied physiology.

[27]  M. Eyssette,et al.  Cardiac output during exercise in paraplegic subjects , 2004, European Journal of Applied Physiology and Occupational Physiology.

[28]  R. Binkhorst,et al.  Cardiac Output of Paraplegics During Exercise , 1984 .

[29]  B. Franklin,et al.  Physical Activity for the Chronically Ill and Disabled , 2000, Sports medicine.

[30]  D. Shurr,et al.  Comparison of Energy Cost and Gait Efficiency During Ambulation in Below-Knee Amputees Using Different Prosthetic Feet—A Preliminary Report , 1988 .

[31]  Edgar Erdfelder,et al.  G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences , 2007, Behavior research methods.

[32]  R. Payne,et al.  A comparative study of the physiological costs of walking in ten bilateral amputees , 2008, Prosthetics and orthotics international.