Gastrointestinal Bleeding Rates in Left Ventricular Assist Device Population Reduced with Octreotide Utilization

Patients with continuous-flow left ventricular assist devices have a high risk of gastrointestinal bleeding (GIB) and recurrent bleeding. Studies have shown octreotide can reduce the risk of GIB. This retrospective, case-crossover study, evaluated the efficacy of octreotide for the prevention of recurrent GIB in patients with left ventricular assist devices between August 2008 and October 2018. A total of 32 patients received octreotide and were included in the study. Hospital admission for GIB was evaluated before and after the initiation of octreotide. Each case served as his/her own control. Most patients were on a reduced aspirin dose (56.2%) and had a reduced international normalized ratio goal (59.4%) before starting monthly octreotide. The most common dose of long-acting octreotide was 30 mg every 28 days. Overall, octreotide decreased the frequency of GIB (4.3 vs. 0.9 events/year, p < 0.001). Nineteen (59.4%) patients did not have a subsequent gastrointestinal bleed. Of the 13 patients who rebled after initiation of octreotide, the frequency of events decreased by 2.6 bleeds per patient per year (4.8 vs. 2.2; p = 0.043). In high-risk patients who have failed conventional therapy, octreotide can be useful for the prevention of recurrent GIB.

[1]  M. Walsh,et al.  A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report , 2019, The New England journal of medicine.

[2]  C. Floroff,et al.  Impact of time in therapeutic range after left ventricular assist device placement: a comparison between thrombus and thrombus-free periods , 2019, Journal of Thrombosis and Thrombolysis.

[3]  E. Rajan,et al.  Danazol treatment of gastrointestinal bleeding in left ventricular assist device-supported patients. , 2018, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  D. Burkhoff,et al.  Long-Acting Octreotide Reduces the Recurrence of Gastrointestinal Bleeding in Patients With a Continuous-Flow Left Ventricular Assist Device. , 2018, Journal of cardiac failure.

[5]  N. Uriel,et al.  Multicenter Evaluation of Octreotide as Secondary Prophylaxis in Patients With Left Ventricular Assist Devices and Gastrointestinal Bleeding , 2017, Circulation. Heart failure.

[6]  R. Malhotra,et al.  Tolerability and Biological Effects of Long-Acting Octreotide in Patients With Continuous Flow Left Ventricular Assist Devices , 2017, ASAIO journal.

[7]  N. Uriel,et al.  A Multicenter Evaluation of Octreotide for Ventricular Assist Device Related Gastrointestinal Bleeding , 2016 .

[8]  G. Ewald,et al.  The HVAD Left Ventricular Assist Device: Risk Factors for Neurological Events and Risk Mitigation Strategies. , 2015, JACC. Heart failure.

[9]  V. Jeevanandam,et al.  Gastrointestinal bleeding in recipients of the HeartWare Ventricular Assist System. , 2015, JACC. Heart failure.

[10]  Shannon Chang,et al.  Characteristics of Gastrointestinal Bleeding After Placement of Continuous-Flow Left Ventricular Assist Device: A Case Series , 2015, Digestive Diseases and Sciences.

[11]  J. Kirklin,et al.  Octreotide in the management of recurrent gastrointestinal bleed in patients supported by continuous flow left ventricular assist devices. , 2015, ASAIO journal.

[12]  A. Guha,et al.  Gastrointestinal bleeding after continuous-flow left ventricular device implantation: review of pathophysiology and management. , 2015, Methodist DeBakey cardiovascular journal.

[13]  D. Banerjee,et al.  Thalidomide for treatment of gastrointestinal angiodysplasia in patients with left ventricular assist devices: case series and treatment protocol. , 2015, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[14]  Ranjit John,et al.  Gastrointestinal bleed after left ventricular assist device implantation: incidence, management, and prevention. , 2014, Annals of cardiothoracic surgery.

[15]  J. Morgan,et al.  Gastrointestinal bleeding with the HeartMate II left ventricular assist device. , 2012, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[16]  Priya Sharma,et al.  Incidence and management of gastrointestinal bleeding with continuous flow assist devices. , 2012, The Annals of thoracic surgery.

[17]  Andrew Boyle,et al.  Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. , 2009, The Journal of thoracic and cardiovascular surgery.