Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle

There is a growing interest in monitoring muscle oxygen saturation (SmO2), which is a localized measure of muscle oxidative metabolism and can be acquired continuously and noninvasively using near‐infrared spectroscopy (NIRS) methods. Most NIRS systems are cumbersome, expensive, fiber coupled devices, with use limited to lab settings. A novel, low cost, wireless, wearable has been developed for use in athletic training. In this study, we evaluate the advantages and limitations of this new simple continuous‐wave (CW) NIRS device with respect to a benchtop, frequency‐domain near‐infrared spectroscopy (FDNIRS) system. Oxygen saturation and hemoglobin/myoglobin concentration in the exercising muscles of 17 athletic individuals were measured simultaneously with the two systems, while subjects performed an incremental test on a stationary cycle ergometer. In addition, blood lactate concentration was measured at the end of each increment with a lactate analyzer. During exercise, the correlation coefficients of the SmO2 and hemoglobin/myoglobin concentrations between the two systems were over 0.70. We also found both systems were insensitive to the presence of thin layers of varying absorption, mimicking different skin colors. Neither system was able to predict the athletes’ lactate threshold power accurately by simply using SmO2 thresholds. Instead, the proprietary software of the wearable device was able to predict the athletes’ lactate threshold power within half of one power increment of the cycling test. These results indicate this novel wearable device may provide a physiological indicator of athlete's exertion.

[1]  P Cerretelli,et al.  Blood lactate accumulation and muscle deoxygenation during incremental exercise. , 1999, Journal of applied physiology.

[2]  J. Bourgois,et al.  An integrated view on the oxygenation responses to incremental exercise at the brain, the locomotor and respiratory muscles , 2016, European Journal of Applied Physiology.

[3]  M Wolf,et al.  Comparison of tissue oximeters on a liquid phantom with adjustable optical properties. , 2016, Biomedical optics express.

[4]  Andrés Hernández,et al.  Blood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians , 2007, Journal of diabetes science and technology.

[5]  T. Yoshikawa,et al.  Which common NIRS variable reflects muscle estimated lactate threshold most closely? , 2006, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.

[6]  Marco Ferrari,et al.  Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy. , 2004, Journal of biomedical optics.

[7]  Yu Shang,et al.  Diffuse optical characterization of an exercising patient group with peripheral artery disease. , 2013, Journal of biomedical optics.

[8]  S. Bailey,et al.  Influence of repeated sprint training on pulmonary O2 uptake and muscle deoxygenation kinetics in humans. , 2009, Journal of applied physiology.

[9]  E Gratton,et al.  Quantitative spectroscopic determination of hemoglobin concentration and saturation in a turbid medium: analysis of the effect of water absorption. , 1997, Journal of biomedical optics.

[10]  A. Lucia,et al.  IMPACT OF TRAINING INTENSITY DISTRIBUTION ON PERFORMANCE IN ENDURANCE ATHLETES , 2007, Journal of strength and conditioning research.

[11]  A. de Haan,et al.  Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold , 2016, PloS one.

[12]  E. Gratton,et al.  Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy. , 1999, Physics in medicine and biology.

[13]  Marco Ferrari,et al.  Muscle oxygenation and pulmonary gas exchange kinetics during cycling exercise on-transitions in humans. , 2003, Journal of applied physiology.

[14]  David Bishop,et al.  Incremental Exercise Test Design and Analysis , 2007, Sports medicine.

[15]  B. Chance,et al.  Spectroscopy and Imaging with Diffusing Light , 1995 .

[16]  Parisa Farzam,et al.  Establishing the diffuse correlation spectroscopy signal relationship with blood flow , 2016, Neurophotonics.

[17]  Per Capita,et al.  About the authors , 1995, Machine Vision and Applications.

[18]  Guoqiang Yu,et al.  Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle. , 2012, Journal of biomedical optics.

[19]  Wearable near Infrared Sensor for Determining an Athlete's Lactate Threshold during Exercise , 2016 .

[20]  Nattai R. Borges,et al.  Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners , 2016, Journal of strength and conditioning research.

[21]  S. Jacques Optical properties of biological tissues: a review , 2013, Physics in medicine and biology.

[22]  Stuart M. C. Lee,et al.  Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement. , 2008, Journal of applied physiology.

[23]  B Chance,et al.  Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers. , 1992, The American journal of physiology.

[24]  Yu Shang,et al.  Noninvasive optical characterization of muscle blood flow, oxygenation, and metabolism in women with fibromyalgia , 2012, Arthritis Research & Therapy.

[25]  A. Yodh,et al.  Diffuse optics for tissue monitoring and tomography , 2010, Reports on progress in physics. Physical Society.

[26]  Erin K. Englund,et al.  Effects of exercise training on calf muscle oxygen extraction and blood flow in patients with peripheral artery disease. , 2017, Journal of applied physiology.

[27]  K. S. Seiler,et al.  Quantifying training intensity distribution in elite endurance athletes: is there evidence for an “optimal” distribution? , 2006, Scandinavian journal of medicine & science in sports.

[28]  W. Hollmann,et al.  Justification of the 4-mmol/l Lactate Threshold , 1985, International journal of sports medicine.

[29]  E. Gratton,et al.  Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry , 1995 .

[30]  Catherine M Hesford,et al.  Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating. , 2012, Medicine and science in sports and exercise.

[31]  Y. Bhambhani,et al.  Detection of ventilatory threshold using near infrared spectroscopy in men and women. , 1997, Medicine and science in sports and exercise.

[32]  B Chance,et al.  Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy. , 1996, Journal of applied physiology.

[33]  M. Joyner,et al.  Regulation of increased blood flow (hyperemia) to muscles during exercise: a hierarchy of competing physiological needs. , 2015, Physiological reviews.

[34]  E Gratton,et al.  Influence of a superficial layer in the quantitative spectroscopic study of strongly scattering media. , 1998, Applied optics.

[35]  Karlman Wasserman,et al.  Changes in skeletal muscle oxygenation during incremental exercise measured with near infrared spectroscopy , 2004, European Journal of Applied Physiology and Occupational Physiology.

[36]  B. Chance,et al.  Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies. , 2005, Journal of biomedical optics.

[37]  M. Ihsan,et al.  Muscle Oxygenation and Blood Volume Reliability during Continuous and Intermittent Running , 2013, International Journal of Sports Medicine.

[38]  T. Barstow,et al.  The noninvasive simultaneous measurement of tissue oxygenation and microvascular hemodynamics during incremental handgrip exercise. , 2018, Journal of applied physiology.

[39]  O. Faude,et al.  Lactate Threshold Concepts , 2009, Sports medicine.

[40]  O. Girard,et al.  Breakpoints in ventilation, cerebral and muscle oxygenation, and muscle activity during an incremental cycling exercise , 2014, Front. Physiol..

[41]  Marco Ferrari,et al.  Muscle Oximetry in Sports Science: A Systematic Review , 2018, Sports Medicine.

[42]  T. Binzoni,et al.  Pulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy , 2013, Physiological measurement.

[43]  Parisa Farzam,et al.  Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis. , 2017, Biomedical optics express.

[44]  Britton Chance,et al.  The use of muscle near-infrared spectroscopy in sport, health and medical sciences: recent developments , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.