Automated parallel DNA sequencing on multiple channel microchips.

We report automated DNA sequencing in 16-channel microchips. A microchip prefilled with sieving matrix is aligned on a heating plate affixed to a movable platform. Samples are loaded into sample reservoirs by using an eight-tip pipetting device, and the chip is docked with an array of electrodes in the focal plane of a four-color scanning detection system. Under computer control, high voltage is applied to the appropriate reservoirs in a programmed sequence that injects and separates the DNA samples. An integrated four-color confocal fluorescent detector automatically scans all 16 channels. The system routinely yields more than 450 bases in 15 min in all 16 channels. In the best case using an automated base-calling program, 543 bases have been called at an accuracy of >99%. Separations, including automated chip loading and sample injection, normally are completed in less than 18 min. The advantages of DNA sequencing on capillary electrophoresis chips include uniform signal intensity and tolerance of high DNA template concentration. To understand the fundamentals of these unique features we developed a theoretical treatment of cross-channel chip injection that we call the differential concentration effect. We present experimental evidence consistent with the predictions of the theory.

[1]  C. Culbertson,et al.  Microchip Structures for Submillisecond Electrophoresis , 1998 .

[2]  R A Mathies,et al.  Capillary array electrophoresis DNA sequencing. , 1999, Analytical chemistry.

[3]  L. Ziaugra,et al.  DNA sequencing on microfabricated electrophoretic devices. , 1998, Analytical chemistry.

[4]  L. Linton,et al.  Toward real-world sequencing by microdevice electrophoresis. , 1999, Genome research.

[5]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[6]  Edward S. Yeung,et al.  Simultaneous monitoring of DNA fragments separated by electrophoresis in a multiplexed array of 100 capillaries , 1994 .

[7]  S. Jacobson,et al.  Multiple sample PCR amplification and electrophoretic analysis on a microchip. , 1998, Analytical chemistry.

[8]  Lloyd M. Smith,et al.  Fluorescence detection in automated DNA sequence analysis , 1986, Nature.

[9]  Takashi Anazawa,et al.  Multiple Sheath-Flow Gel Capillary-Array Electrophoresis for Multicolor Fluorescent DNA Detection , 1994 .

[10]  N. Dovichi,et al.  Use of non-cross-linked polyacrylamide for four-color DNA sequencing by capillary electrophoresis separation of fragments up to 640 bases in length in two hours. , 1995, Analytical chemistry.

[11]  A. Woolley,et al.  High-speed DNA genotyping using microfabricated capillary array electrophoresis chips. , 1997, Analytical chemistry.

[12]  D. J. Harrison,et al.  Capillary electrophoresis and sample injection systems integrated on a planar glass chip , 1992 .

[13]  Andreas Manz,et al.  High-Speed Separation of Antisense Oligonucleotides on a Micromachined Capillary Electrophoresis Device , 1994 .

[14]  S. Jacobson,et al.  Integrated microdevice for DNA restriction fragment analysis. , 1996, Analytical chemistry.

[15]  A. Woolley,et al.  Ultra-high-speed DNA sequencing using capillary electrophoresis chips. , 1995, Analytical chemistry.

[16]  R A Mathies,et al.  Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels. , 1999, Analytical chemistry.

[17]  Arthur W. Miller,et al.  The use of elevated column temperature to extend DNA sequencing read lengths in capillary electrophoresis with replaceable polymer matrices , 1996, Electrophoresis.

[18]  J. Michael Ramsey,et al.  Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices , 1994 .

[19]  P. Belgrader,et al.  DNA typing in thirty seconds with a microfabricated device. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[20]  Richard A. Mathies,et al.  Microfabrication Technology for the Production of Capillary Array Electrophoresis Chips , 1998 .

[21]  D. J. Harrison,et al.  Planar chips technology for miniaturization and integration of separation techniques into monitoring systems. Capillary electrophoresis on a chip , 1992 .

[22]  K Watanabe,et al.  Extraordinarily stable mini-hairpins: electrophoretical and thermal properties of the various sequence variants of d(GCGAAAGC) and their effect on DNA sequencing. , 1992, Nucleic acids research.

[23]  J. Michael Ramsey,et al.  Precolumn Reactions with Electrophoretic Analysis Integrated on a Microchip , 1994 .

[24]  P. Boček,et al.  Injection bias of DNA fragments in capillary electrophoresis with sieving. , 1995, Journal of chromatography. A.

[25]  D P Glavin,et al.  Microfabricated capillary electrophoresis amino acid chirality analyzer for extraterrestrial exploration. , 1999, Analytical chemistry.

[26]  Richard A. Mathies,et al.  Capillary array electrophoresis: an approach to high-speed, high-throughput DNA sequencing , 1992, Nature.

[27]  N. Dovichi DNA sequencing by capillary electrophoresis , 1997, Electrophoresis.

[28]  L. Kotler,et al.  A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol. , 1998, Analytical chemistry.

[29]  A. Manz,et al.  Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heights , 1993 .

[30]  S. Jacobson,et al.  High-Speed Separations on a Microchip , 1994 .

[31]  Stellan Hjertén,et al.  High-performance electrophoresis : Elimination of electroendosmosis and solute adsorption , 1985 .

[32]  E Pennisi,et al.  Academic Sequencers Challenge Celera in a Sprint to the Finish , 1999, Science.

[33]  J. Mullikin,et al.  Sequencing the Genome, Fast , 1999, Science.

[34]  R. Mathies,et al.  Radial capillary array electrophoresis microplate and scanner for high-performance nucleic acid analysis. , 1999, Analytical chemistry.

[35]  Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions. , 1998, Analytical chemistry.

[36]  L. Kotler,et al.  A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis. , 1998, Analytical chemistry.

[37]  R A Mathies,et al.  High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[38]  A. Woolley,et al.  Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips. , 1994, Proceedings of the National Academy of Sciences of the United States of America.