Influence of longitudinal fire location on smoke characteristics under the tunnel ceiling

Summary The critical ventilation velocity is almost the most well-investigated fire phenomenon in the tunnel fire research field whereas previous studies have always investigated it when the fire source is distant from the downstream tunnel exit. Fortunately, a recent study provided a set of data on the critical ventilation velocity for tunnel fires occurring near tunnel exits by small-scaled experiments, nevertheless, with a lack of further analysis. To demonstrate the relationship of the critical ventilation velocity and the distance between the fire and tunnel exit more explicitly and detailedly, a quantitative and graphical study was carried out and a correlation was presented in this paper. Inspired by this, a set of small-scaled experiments were carried out to investigate the influence of different longitudinal fire locations on maximum smoke temperature under the tunnel ceiling. Results show that unlike the critical ventilation velocity, the maximum smoke temperature was not obviously affected by longitudinal fire location. Copyright © 2014 John Wiley & Sons, Ltd.

[2]  Pascal Boulet,et al.  Experimental and numerical study of fire in a midscale test tunnel , 2012 .

[3]  Haukur Ingason,et al.  Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires , 2010 .

[4]  Haukur Ingason,et al.  The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires , 2011 .

[5]  Haukur Ingason,et al.  State of the Art of Tunnel Fire Research , 2008 .

[6]  Dong Hyeon Kim,et al.  Critical velocity and burning rate in pool fire during longitudinal ventilation , 2007 .

[7]  Chuangang Fan,et al.  Experimental study on transverse smoke temperature distribution in road tunnel fires , 2013 .

[8]  Shouxiang Lu,et al.  Initial fuel temperature effects on burning rate of pool fire. , 2011, Journal of hazardous materials.

[9]  Kuang-Chung Tsai,et al.  Critical ventilation velocity for multi-source tunnel fires , 2010 .

[10]  Jie Ji,et al.  Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling , 2012 .

[11]  Heping Zhang,et al.  Effect of longitudinal ventilation on heat release rate of tunnel fires , 2012 .

[12]  T. Steinhaus,et al.  Large-scale pool fires , 2007 .

[13]  Jie Ji,et al.  A study of the effect of plug-holing and boundary layer separation on natural ventilation with vertical shaft in urban road tunnel fires , 2012 .

[14]  K. L. Tay,et al.  Control of Ventilation Airflow for Tunnel Fire Safety , 2000 .

[15]  C. C. Hwang,et al.  The critical ventilation velocity in tunnel fires—a computer simulation , 2005 .

[16]  Xudong Cheng,et al.  Effect of blockage ratio on the maximum temperature under the ceiling in tunnel fires , 2013 .

[17]  Kuang-Chung Tsai,et al.  Critical ventilation velocity for tunnel fires occurring near tunnel exits , 2011 .

[18]  Bo Lei,et al.  Experimental and Theoretical Study for Tunnel Fires with Natural Ventilation , 2013, Fire Technology.

[19]  James G. Quintiere,et al.  Enclosure Fire Dynamics , 1999 .

[20]  Alex Bwalya An Overview of Design Fires for Building Compartments , 2008 .

[21]  Haukur Ingason,et al.  The maximum ceiling gas temperature in a large tunnel fire , 2012 .

[22]  Jie Ji,et al.  A simplified calculation method on maximum smoke temperature under the ceiling in subway station fires , 2011 .

[23]  Jie Ji,et al.  Influence of longitudinal wind on natural ventilation with vertical shaft in a road tunnel fire , 2013 .

[24]  Kuang-Chung Tsai,et al.  Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels , 2012 .

[25]  Anthony P. Hamins,et al.  Global Combustion Behavior of 1 MW to 3 MW Hydrocarbon Spray Fires Burning in an Open Environment (NISTIR 7013) | NIST , 2003 .

[26]  Alvin C.K. Lai,et al.  Impact of location of jet fan on airflow structure in tunnel fire , 2012 .

[27]  Grunde Jomaas,et al.  Experimental Study on the Burning Behavior of Pool Fires in Rooms with Different Wall Linings , 2012 .

[28]  Jie Ji,et al.  Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires , 2013 .

[29]  Hx X. Chen,et al.  Wind tunnel tests on compartment fires with crossflow ventilation , 2011 .

[30]  Hong Sun Ryou,et al.  Tunnel Fires: Experiments on Critical Velocity and Burning Rate in Pool Fire During Longitudinal Ventilation , 2007 .

[31]  M. Spearpoint,et al.  Numerical simulation of scale‐model smoke contamination of upper atrium levels by a channelled balcony spill plume , 2013 .