Analysis, Design and Control of a Unified Power-Quality Conditioner Based on a Current-Source Topology

This paper presents a three-phase unified power-quality conditioner based on current source converters (CSC-UPQC), including the design guidelines of the key components, an appropriate control scheme, and a selection procedure of the dc current level. Particularly, the ride through capability criterion is used to define a minimum dc current level so that the CSC-UPQC achieves the same characteristics as a UPQC based on voltage-source converters in terms of voltage disturbance compensation in the point of common coupling (PCC) and load power factor compensation. A 1.17 MVA load fed from a 3.3 kV system is used to show the proposed design procedure, and a laboratory prototype is implemented to show the system compensating sags and swells using low switching frequency in the CSC and maintaining a unitary displacement power factor in the PCC.

[1]  C.A. Sepulveda,et al.  A Mixed LQRI / PI based Control for Three-Phase UPQCs , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[2]  Kenneth P. Phillips Current-Source Converter for AC Motor Drives , 1972 .

[3]  J.R. Espinoza,et al.  Modeling Issues in Three-Phase Current Source Rectifiers that use Damping Resistors , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[4]  G. Joos,et al.  Input filter design for PWM current-source rectifiers , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[5]  J.R. Espinoza,et al.  Analysis and design of a linear control strategy for three-phase UPQCs , 2004, 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004.

[6]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[7]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[8]  Hirofumi Akagi,et al.  The unified power quality conditioner: The integration of series active filters and shunt active filters , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[9]  José R Espinoza,et al.  Decoupled control of a Unified Power Quality Conditioner based on a current source topology for fast AC mains disturbance compensation , 2010, 2010 IEEE International Conference on Industrial Technology.

[10]  K. Vadirajacharya,et al.  A Simple control strategy for Unified Power Quality Conditioner using current source inverter , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[11]  Alfred Rufer,et al.  Unified power quality conditioner based on current source converter topology , 2001 .

[12]  Geza Joos,et al.  State variable decoupling and power flow control in PWM current-source rectifiers , 1998, IEEE Trans. Ind. Electron..

[13]  E. Gunther,et al.  A survey of distribution system power quality-preliminary results , 1995 .

[14]  M. J. Samotyj,et al.  Voltage sags in industrial systems , 1991, Conference Record. Industrial and Commercial Power Systems Technical Conference 1991.

[15]  Hirofumi Akagi Trends in active power line conditioners , 1994 .