Towards a portable laser speckle based device to evaluate the level of atrophy in tissue

In this research we outline the optical background and manufacture of the OPTA device: an Optical Probe to evaluate Tissue Atrophy. We present a portable profiling system capable of directly interrogating the integrity of human skin in vivo. The device utilizes laser speckle and spectral imaging modalities to measure a suite of physical parameters to aid clinical assessment, in particular surface roughness and blood oxygenation. We provide a detailed discussion on the relation between laser speckle scattering and the influence of surface texture. This leads us to discuss how these measurements can relate a participant’s perception of skin pathologies in vivo and discuss the potential clinical application. We will first discuss the technical information relating to the design and assembly of the Optical Probe to evaluate Tissue Atrophy (OPTA) probe, utilizing a biocompatible 3D printing material, polymer optical fibers and custom miniature cage system optics. Finally, we will present the practical use of this device using our results of a pilot study to trial the OPTA device, in house.

[1]  J. Girkin,et al.  Quantitative high dynamic range beam profiling for fluorescence microscopy. , 2014, The Review of scientific instruments.

[2]  Stephen W. James,et al.  Dissolved Oxygen Sensing Using an Optical Fiber Long Period Grating Coated With Hemoglobin , 2015, Journal of Lightwave Technology.

[3]  Bruce Alberts,et al.  Essential Cell Biology , 1983 .

[4]  T G van Leeuwen,et al.  Speckles in laser Doppler perfusion imaging. , 2006, Optics letters.

[5]  John M. Girkin,et al.  Random laser illumination: an ideal source for biomedical polarization imaging? , 2016, SPIE BiOS.

[6]  Kejia Li,et al.  A Wireless Reflectance Pulse Oximeter With Digital Baseline Control for Unfiltered Photoplethysmograms , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[7]  S. Prahl Light transport in tissue , 1988 .

[8]  Zhan Gao,et al.  Adaptive pulse oximeter with dual-wavelength based on wavelet transforms. , 2013, Optics express.

[9]  John M. Girkin,et al.  Quantification of skin quality through speckle analysis , 2015, Photonics West - Biomedical Optics.

[10]  L. Mackenzie In vivo microvascular oximetry using multispectral imaging , 2016 .

[11]  Isaac Freund,et al.  Joseph W. Goodman: Speckle Phenomena in Optics: Theory and Applications , 2007 .

[12]  Lioudmila Tchvialeva,et al.  Influence of geometry on polychromatic speckle contrast. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[13]  M. Stern,et al.  Laser Doppler velocimetry in blood and multiply scattering fluids: theory. , 1985, Applied optics.

[14]  Lioudmila Tchvialeva,et al.  Surface roughness measurement by speckle contrast under the illumination of light with arbitrary spectral profile , 2010 .

[15]  J. Goodman Some fundamental properties of speckle , 1976 .

[16]  J. Briers,et al.  Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. , 2001, Physiological measurement.

[17]  Andrew R. Harvey,et al.  Oximetry using multispectral imaging: theory and application , 2018 .

[18]  J. Goodman Speckle Phenomena in Optics: Theory and Applications , 2020 .