A label-free fiber optic SPR biosensor for specific detection of C-reactive protein

[1]  F. Arregui,et al.  High sensitive and selective C-reactive protein detection by means of lossy mode resonance based optical fiber devices. , 2017, Biosensors & bioelectronics.

[2]  F. Baldini,et al.  SPR‐based plastic optical fibre biosensor for the detection of C‐reactive protein in serum , 2016, Journal of biophotonics.

[3]  S. Vermeire,et al.  Fiber optic-SPR platform for fast and sensitive infliximab detection in serum of inflammatory bowel disease patients. , 2016, Biosensors & bioelectronics.

[4]  Yuzhi Chen,et al.  Fiber-optic urine specific gravity sensor based on surface plasmon resonance , 2016 .

[5]  Zhimin He,et al.  A polydopamine-modified optical fiber SPR biosensor using electroless-plated gold films for immunoassays. , 2015, Biosensors & bioelectronics.

[6]  Lin Zhang,et al.  Biosensor based on excessively tilted fiber grating in thin-cladding optical fiber for sensitive and selective detection of low glucose concentration. , 2015, Optics express.

[7]  Yi-Wei Shi,et al.  Hollow fiber surface plasmon resonance sensor for the detection of liquid with high refractive index. , 2013, Optics express.

[8]  Yuzhi Chen,et al.  Real-time measurement with a fiber optical surface plasmon resonance sensor for biochemical interaction analysis , 2013, 1905.03464.

[9]  Jeroen Lammertyn,et al.  Selection of aptamers against Ara h 1 protein for FO-SPR biosensing of peanut allergens in food matrices. , 2013, Biosensors & bioelectronics.

[10]  Wolfgang J. Parak,et al.  Time-Resolved Fluorescence Immunoassay for C-Reactive Protein Using Colloidal Semiconducting Nanoparticles , 2011, Sensors.

[11]  P Meyrueis,et al.  Fiber optic Surface Plasmon Resonance sensor based on wavelength modulation for hydrogen sensing. , 2011, Optics express.

[12]  Liyun Ding,et al.  Numerical investigation for SPR-based optical fiber sensor , 2011 .

[13]  Arthur Chiou,et al.  Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics. , 2007, Journal of biomedical optics.

[14]  N. Miura,et al.  Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest , 2007 .

[15]  Haowen Huang,et al.  Label-free reading of microarray-based proteins with high throughput surface plasmon resonance imaging. , 2006, Biosensors & bioelectronics.

[16]  Norio Miura,et al.  Highly sensitive and interference-free simultaneous detection of two polycyclic aromatic hydrocarbons at parts-per-trillion levels using a surface plasmon resonance immunosensor , 2004 .

[17]  K. Gomi,et al.  A new immuno quantitative method by latex agglutination--application for the determination of serum C-reactive protein (CRP) and its clinical significance. , 1986, Journal of clinical & laboratory immunology.

[18]  J. Tomasi,et al.  Use of whole Streptococcus pneumoniae cells as a solid phase sorbent for C-reactive protein measurement by ELISA. , 1985, JIM - Journal of Immunological Methods.

[19]  A. Gautier,et al.  C-reactive protein , 2005 .

[20]  M. Mccarty THE OCCURRENCE DURING ACUTE INFECTIONS OF A PROTEIN NOT NORMALLY PRESENT IN THE BLOOD , 1947, The Journal of experimental medicine.

[21]  C. Aring,et al.  A CRITICAL REVIEW , 1939, Journal of neurology and psychiatry.

[22]  Thomas Francis,et al.  SEROLOGICAL REACTIONS IN PNEUMONIA WITH A NON-PROTEIN SOMATIC FRACTION OF PNEUMOCOCCUS , 1930, The Journal of experimental medicine.

[23]  B. Young,et al.  C‐Reactive Protein: A Critical Review , 1991, Pathology.