A critical approach to the determination of optimal heat rejection pressure in transcritical systems

Abstract In this paper the optimal energy efficiency and high cycle pressure problem in single-stage refrigerating carbon dioxide vapour compressor units operating in transcritical conditions is addressed. Literature approximated solutions to the optimisation problem are analysed and critically discussed. A numerical model for CO 2 heat exchangers and refrigerant systems is developed. Different gas coolers are simulated in order to investigate the effect of literature simplifying assumptions on the optimal pressure determination: the analysis showed a strong sensitivity of the gas cooler outlet temperature from the secondary fluid temperature, from its capacity rate and from the heat exchanger geometry. Nevertheless it resulted that approximated solutions obtained considering the carbon dioxide gas cooler outlet temperature as an independent variable behaved better than solutions correlating it to secondary fluid inlet temperature. A commercial refrigeration plant and a heat pump water heater were finally simulated to verify their energy performances when applying literature approximated solutions in presence of an on-board compressor capacity and supply water temperature control respectively. While in the case of the commercial refrigeration plant no major penalisation resulted from the literature approximated solutions simplifying assumptions, the heat pump performance was strongly deteriorated, up to −30%, as a consequence of the huge variation in the water capacity flow rate resulting from the water temperature control. It was finally concluded that an approximated correlation should be critically evaluated before implementation; a real-time algorithm for determining the optimal (or quasi-optimal) pressure value could provide a more efficient and robust solution.

[1]  G. Lorentzen Revival of carbon dioxide as a refrigerant , 1994 .

[2]  Marco Corradi,et al.  Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution , 2005 .

[3]  Junjie Gu,et al.  The optimum high pressure for CO2 transcritical refrigeration systems with internal heat exchangers , 2005 .

[4]  Chi-Chuan Wang,et al.  Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation , 2000 .

[5]  Marco Corradi,et al.  Thermodynamic analysis of different two-stage transcritical carbon dioxide cycles , 2009 .

[6]  Luca Cecchinato,et al.  Design and experimental analysis of a carbon dioxide transcritical chiller for commercial refrigeration , 2008 .

[7]  John R. Thome,et al.  New flow boiling heat transfer model and flow pattern map for carbon dioxide evaporating inside horizontal tubes , 2006 .

[8]  Jahar Sarkar,et al.  Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications , 2004 .

[9]  Petter Nekså,et al.  Commercial refrigeration system using CO2 as the refrigerant , 2004 .

[10]  Marco Corradi,et al.  Optimisation of the throttling system in a CO2 refrigerating machine , 2003 .

[11]  Marco Corradi,et al.  An Assessment of Heat Transfer through Fins in a Fin-and-Tube Gas Cooler for Transcritical Carbon Dioxide Cycles , 2007 .

[12]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[13]  Liu Hongsheng,et al.  Experimental investigation of a CO2 automotive air conditioner , 2005 .

[14]  Petter Nekså,et al.  CO2 heat pump systems , 2002 .

[15]  W. Wagner,et al.  A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple‐Point Temperature to 1100 K at Pressures up to 800 MPa , 1996 .

[16]  Reinhard Radermacher,et al.  Numerical approach for modeling air-to-refrigerant fin-and-tube heat exchanger with tube-to-tube heat transfer , 2008 .

[17]  Friedrich Kauf,et al.  Determination of the optimum high pressure for transcritical CO2-refrigeration cycles , 1999 .

[18]  Jostein Pettersen,et al.  Fundamental process and system design issues in CO2 vapor compression systems , 2004 .

[19]  Shengming Liao,et al.  A correlation of optimal heat rejection pressures in transcritical carbon dioxide cycles , 2000 .

[20]  Ramón Cabello,et al.  Experimental evaluation of the energy efficiency of a CO2 refrigerating plant working in transcritical conditions , 2008 .

[21]  O. G. Martynenko,et al.  Handbook of hydraulic resistance , 1986 .

[22]  C. Dang,et al.  In-tube cooling heat transfer of supercritical carbon dioxide. Part 1. Experimental measurement , 2004 .

[23]  P. Nekså,et al.  CO2-heat pump water heater: characteristics, system design and experimental results , 1998 .

[24]  Silvia Minetto,et al.  CO2 heat pump for domestic hot water. , 2008 .

[25]  Piotr A. Domanski,et al.  Comparitive analysis of an automotive air conditioning systems operating with CO2 and R134a , 2002 .

[26]  M. J. D. Powell,et al.  Restart procedures for the conjugate gradient method , 1977, Math. Program..

[27]  Haruhisa Inokuty Approximate Graphical Method of Finding Compression Pressure of CO_2 Refrigerating Machine for Max. Coefficient of Performance , 1923 .

[28]  Jahar Sarkar,et al.  Natural refrigerant-based subcritical and transcritical cycles for high temperature heating , 2007 .