A US-wide power systems frequency monitoring network

Frequency dynamics is one of the most important measures of an electrical power system. To better understand power system dynamics, accurately measured wide-area frequency is needed. The concept of building an Internet based real-time GPS synchronized wide area frequency monitoring network (FNET) was proposed in 2000, and the actual system has been deployed. The FNET system consists of frequency disturbance recorders (FDR) and an information management system (IMS). The FNET has made the synchronized observations of the entire US power network possible for the first time. This paper summarizes the implementation of the FNET system and shows some preliminary observations and analyses of the data that has been collected from the FNET.

[1]  J.F. Hauer,et al.  Performance of "WAMS East" in providing dynamic information for the North East blackout of August 14, 2003 , 2004, IEEE Power Engineering Society General Meeting, 2004..

[2]  B. Bhargava Synchronized Phasor Measurement System project at Southern California Edison Co , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[3]  M.R. Iravani,et al.  Estimation of frequency and its rate of change for applications in power systems , 2004, IEEE Transactions on Power Delivery.

[4]  C. Rehtanz,et al.  Experiences with and perspectives of the system for wide area monitoring of power systems , 2003, CIGRE/IEEE PES International Symposium Quality and Security of Electric Power Delivery Systems, 2003. CIGRE/PES 2003..

[5]  A. Haghighat,et al.  Performance of A 3 MCNP™ for Calculation of 3-D Neutron Flux Distribution in a BWR Core Shroud , 2001 .

[6]  Ling Chen,et al.  Internet based frequency monitoring network (FNET) , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[7]  George J. Cokkinides,et al.  Multifunctional synchronized measurement network [power systems] , 1998 .

[8]  R.P. Schulz,et al.  Applications of fast phasor measurements on utility systems , 1989, Conference Papers Power Industry Computer Application Conference.

[9]  George J. Cokkinides,et al.  MULTIFUNCTIONAL SYNCHRONIZED MEASUREMENT NETWORK , 1998 .

[10]  James S. Thorp,et al.  Application of synchronised phasor measurements to real-time transient stability prediction , 1995 .

[11]  T. Baldwin,et al.  Power system observability with minimal phasor measurement placement , 1993 .

[12]  Kenneth E. Martin,et al.  Visualizing Real-Time Security Threats Using Hybrid SCADA / PMU Measurement Displays , 2005, Proceedings of the 38th Annual Hawaii International Conference on System Sciences.

[13]  Jian Chen,et al.  Accurate frequency estimation with phasor angles , 1994 .

[14]  Christian Rehtanz,et al.  Wide area measurement and protection system for emergency voltage stability control , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[15]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[16]  J. F. Hauer Validation of phasor calculations in the macrodyne PMU for California-Oregon Transmission Project tests of March 1993 , 1996 .

[17]  Edward J. Powers,et al.  Time-frequency analysis of power system disturbance signals for power quality , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[18]  Joe H. Chow,et al.  Power system disturbance identification from recorded dynamic data at the Northfield substation , 2003 .

[19]  Innocent Kamwa,et al.  Wide-area measurement based stabilizing control of large power systems-a decentralized/hierarchical approach , 2001 .

[20]  S. Ganesan,et al.  Maximizing power system stability through wide area protection , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[21]  R.O. Burnett,et al.  Power system applications for phasor measurement units , 1994, IEEE Computer Applications in Power.

[22]  John Ballance,et al.  Use of Synchronized Phasor measurement System for Enhancing AC-DC Power System Transmission Reliability and Capability , 2004 .

[23]  O. Saeki,et al.  Oscillation mode analysis in power systems based on data acquired by distributed phasor measurement units , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[24]  Adrian Halinka,et al.  Accurate measurement of wide-range power system frequency changes for generator protection , 1997 .

[25]  S. E. Stanton,et al.  Application of phasor measurements and partial energy analysis in stabilizing large disturbances , 1995 .

[26]  T.W. Cease,et al.  Real-time monitoring of the TVA power system , 1994, IEEE Computer Applications in Power.

[27]  Chen-Ching Liu Strategic power infrastructure defense (SPID): a wide area protection and control system , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[28]  J. F. Hauer,et al.  The DOE Wide Area Measurement System (WAMS) Project: Demonstration of dynamic information technology for the future power system , 1995 .