Clinical events following excimer laser angioplasty or balloon angioplasty for complex coronary lesions: subanalysis of a randomised trial

Objectives To compare clinical outcome in patients with complex coronary lesions treated with either excimer laser coronary angioplasty (ELCA) or balloon angioplasty. Patients and design 308 patients with stable angina and a coronary lesion of more than 10 mm in length were randomised to ELCA (151 patients, 158 lesions) or balloon angioplasty (157 patients, 167 lesions). The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomised segment during six months of follow up. Subanalysis was performed to identify a subgroup of patients with a beneficial clinical outcome following ELCA or balloon angioplasty. Setting Two university hospitals and one general hospital. Results There were no deaths. Myocardial infarction, coronary bypass surgery, and repeated angioplasty occurred in 4.6, 10.6, and 21.2%, respectively, of patients treated with ELCA compared with 5.7, 10.8, and 18.5%, respectively, of those treated with balloon angioplasty. ELCA did not yield a favourable clinical outcome in subgroups of patients with long (more than 20 mm) coronary lesions, calcified lesions, small diseased vessels (⩽2.5 mm reference diameter), or total coronary occlusions. There was a worse clinical outcome in patients with tandem lesions treated with ELCA compared with balloon angioplasty (9/18 v 3/26 lesions; p = 0.01); while a trend towards an unfavourable clinical outcome was found in patients with vessels with a reference diameter of more than 2.5 mm (23/66 v 13/63 lesions, p = 0.07) and left circumflex coronary lesions (12/41 v 6/42 lesions, p = 0.08). Conclusions The findings indicate a worse clinical outcome in patients with lesions of more than 10 mm treated with ELCA compared with balloon angioplasty who have tandem coronary lesions and in those with vessels with a reference diameter of more than 2.5 mm and left circumflex coronary lesions.

[1]  F. Schwarz,et al.  Randomized comparison of angioplasty of complex coronary lesions at a single center. Excimer Laser, Rotational Atherectomy, and Balloon Angioplasty Comparison (ERBAC) Study. , 1997, Circulation.

[2]  J. Tijssen,et al.  Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease , 1996, The Lancet.

[3]  M. Leon,et al.  Intravascular ultrasound comparison of restenotic and de novo coronary artery narrowings. , 1994, The American journal of cardiology.

[4]  D. Baim,et al.  Elevation of the creatine kinase myocardial isoform following otherwise successful directional coronary atherectomy and stenting. , 1994, The American journal of cardiology.

[5]  R. Califf,et al.  A Comparison of Directional Atherectomy with Coronary Angioplasty in Patients with Coronary Artery Disease , 1993 .

[6]  P. Serruys,et al.  Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty. CARPORT and MERCATOR Study Groups. , 1993, The American journal of cardiology.

[7]  T G van Leeuwen,et al.  Intraluminal Vapor Bubble Induced by Excimer Laser Pulse Causes Microsecond Arterial Dilation and Invagination Leading to Extensive Wall Damage in the Rabbit , 1993, Circulation.

[8]  J. Tijssen,et al.  Excimer laser coronary angioplasty in The Netherlands: preamble for a randomized study. , 1993, American heart journal.

[9]  S. Ellis,et al.  Clinical success, complications and restenosis rates with excimer laser coronary angioplasty. The Percutaneous Excimer Laser Coronary Angioplasty Registry. , 1992, The American journal of cardiology.

[10]  R D Safian,et al.  The Importance of Acute Luminal Diameter in Determining Restenosis After Coronary Atherectomy or Stenting , 1992, Circulation.

[11]  J. Bittl,et al.  Excimer Laser‐Facilitated Coronary Angioplasty: Relative Risk Analysis of Acute and Follow‐up Results in 200 Patients , 1992, Circulation.

[12]  T G van Leeuwen,et al.  Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. , 1992, Journal of the American College of Cardiology.

[13]  M. Leon,et al.  Excimer Laser Coronary Angioplasty of Aorto‐Ostial Stenoses Results of the Excimer Laser Coronary Angioplasty (ELCA) Registry in the First 200 Patients , 1992, The American journal of cardiology.

[14]  J. Forrester,et al.  Percutaneous Excimer Laser Coronary Angioplast of Lesions Not Ideal for Balloon Angioplasty , 1991, Circulation.

[15]  L. Klein,et al.  Incidence and clinical significance of transient creatine kinase elevations and the diagnosis of non-Q wave myocardial infarction associated with coronary angioplasty. , 1991, Journal of the American College of Cardiology.

[16]  E J Topol,et al.  Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Multivessel Angioplasty Prognosis Study Group. , 1990, Circulation.

[17]  S. String,et al.  Laser ablation of human atherosclerotic plaque without adjacent tissue injury: Grundfest WS, Litvack F, Forrester JS, et al. J Am Coll Cardiol 1985; 5: 929-33 , 1986 .

[18]  M A Konstam,et al.  The excimer laser: gross, light microscopic and ultrastructural analysis of potential advantages for use in laser therapy of cardiovascular disease. , 1985, Journal of the American College of Cardiology.

[19]  W S Grundfest,et al.  Laser ablation of human atherosclerotic plaque without adjacent tissue injury. , 1985, Journal of the American College of Cardiology.

[20]  L. Campeau Letter: Grading of angina pectoris. , 1976, Circulation.

[21]  Geert G. Verhoofstad,et al.  Tissue ablation and gas formation of two excimer laser systems: An in vitro evaluation on porcine aorta , 1996, Lasers in surgery and medicine.

[22]  A. Baumbach,et al.  Formation of pressure waves during in vitro excimer laser irradiation in whole blood and the effect of dilution with contrast media and saline , 1994, Lasers in surgery and medicine.

[23]  H. Oswald,et al.  Clinical results of coronary excimer laser angioplasty: report from the European Coronary Excimer Laser Angioplasty Registry. , 1994, European heart journal.

[24]  D. Krauthamer Percutaneous excimer laser coronary angioplasty: results in the first consecutive 3,000 patients. The ELCA Investigators , 1994 .

[25]  P. Serruys,et al.  Quantitative Coronary Angiography in Clinical Practice , 1994, Developments in Cardiovascular Medicine.

[26]  M. V. van Gemert,et al.  Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline , 1992, Lasers in surgery and medicine.

[27]  Roland Sauerbrey,et al.  Tissue interactions and measurement of ablation rates with ultraviolet and visible lasers in canine and human arteries , 1987, Lasers in surgery and medicine.

[28]  H. S. Mueller,et al.  The Thrombolysis in Myocardial Infarction (TIMI) trial. Phase I findings. , 1985, The New England journal of medicine.