High Frequency, High Temperature Specific Core Loss and Dynamic B-H Hysteresis Loop Characteristics of Soft Magnetic Alloys
暂无分享,去创建一个
Limited experimental data exists for the specific core loss and dynamic B-H loops for soft magnetic materials for the combined conditions of high frequency and high temperature. This experimental study investigates the specific core loss and dynamic B-H loop characteristics of Supermalloy and Metglas 2605SC over the frequency range of 1-50 kHz and temperature range of 23-300 C under sinusoidal voltage excitation. The experimental setup used to conduct the investigation is described. The effects of the maximum magnetic flux density, frequency, and temperature on the specific core loss and on the size and shape of the B-H loops are examined.
[1] Harry A. Owen,et al. High-frequency measurement techniques for magnetic cores , 1990 .
[2] Harry A. Owen,et al. High-frequency characteristics of amorphous metallic-alloy tape-wound cores , 1983, 1983 IEEE Power Electronics Specialists Conference.
[3] T. Wilson,et al. High-frequency core-loss characteristics of biased Fe 79 B 16 Si 5 amorphous metallic-alloy tape-wound cores , 1984 .
[4] Harry A. Owen,et al. High-frequency measurement techniques for magnetic cores , 1985, 1985 IEEE Power Electronics Specialists Conference.