Two-reference swept-source optical coherence tomography of high operation flexibility.

The significantly less stringent operation of a two-reference swept-source optical coherence tomography (OCT) system for suppressing the mirror image is demonstrated based on the spatially localized image processing method. With this method, the phase difference between the two reference signals is not limited to 90 degrees. Based on the current experimental operation, the mirror image can be effectively suppressed as long as the phase difference is larger than 20 degrees. In other words, the adjustment of the beam splitter orientation for controlling the phase difference becomes much more flexible. Also, based on a phantom experiment, the combination the spatially localized mirror image suppression method with the two-reference OCT operation leads to the implementation of full-range optical Doppler tomography.

[1]  J. Izatt,et al.  Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line , 2011, Biomedical optics express.

[2]  Zhongping Chen,et al.  Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator. , 2005, Optics letters.

[3]  S. Yun,et al.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting. , 2004, Optics express.

[4]  Kai Wang,et al.  Sinusoidal B-M method based spectral domain optical coherence tomography for the elimination of complex-conjugate artifact. , 2009, Optics express.

[5]  G J Streekstra,et al.  Multiple scattering effects in Doppler optical coherence tomography of flowing blood , 2012, Physics in medicine and biology.

[6]  Michael Pircher,et al.  Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography. , 2010, Optics letters.

[7]  Jannick P. Rolland,et al.  Doppler imaging with dual-detection full-range frequency domain optical coherence tomography , 2010, Biomedical optics express.

[8]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[9]  Joseph A. Izatt,et al.  Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal , 2005, SPIE BiOS.

[10]  Y. Yasuno,et al.  Full-range, high-speed, high-resolution 1 microm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. , 2008, Optics express.

[11]  Ruikang K. Wang In vivo full range complex Fourier domain optical coherence tomography , 2007 .

[12]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[13]  Sébastien Vergnole,et al.  Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher. , 2008, Optics letters.

[14]  Toyohiko Yatagai,et al.  One-shot-phase-shifting Fourier domain optical coherence tomography by reference wavefront tilting. , 2004, Optics express.

[15]  R. Leitgeb,et al.  Complex ambiguity-free Fourier domain optical coherence tomography through transverse scanning. , 2007, Optics letters.

[16]  Shuichi Makita,et al.  Parabolic BM-scan technique for full range Doppler spectral domain optical coherence tomography. , 2010, Optics express.

[17]  Chiung-Ting Wu,et al.  Method for suppressing the mirror image in Fourier-domain optical coherence tomography. , 2011, Optics letters.

[18]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[19]  Maciej Wojtkowski,et al.  Complex spectral OCT in human eye imaging in vivo , 2004 .

[20]  R. Leitgeb,et al.  High speed full range complex spectral domain optical coherence tomography. , 2005, Optics express.

[21]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[22]  Chiung-Ting Wu,et al.  Computation time-saving mirror image suppression method in Fourier-domain optical coherence tomography. , 2012, Optics express.

[23]  Zhongping Chen,et al.  Full range polarization-sensitive Fourier domain optical coherence tomography. , 2004, Optics express.

[24]  Kye-Sung Lee,et al.  Dual-reference full-range frequency domain optical coherence tomography , 2009, BiOS.

[25]  T. Yatagai,et al.  Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography. , 2006, Applied optics.

[26]  Ruikang K. Wang,et al.  Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography. , 2007, Optics letters.

[27]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.