Monte Carlo simulation of a computed tomography x-ray tube

The dose delivered to patients during computed tomography (CT) exams has increased in the past decade. With the increasing complexity of CT examinations, measurement of the dose becomes more difficult and more important. In some cases, the standard methods, such as measurement of the computed tomography dose index (CTDI), are currently under question. One approach to determine the dose from CT exams is to use Monte Carlo (MC) methods. Since the patient geometry can be included in the model, Monte Carlo simulations are potentially the most accurate method of determining the dose delivered to patients. In this work, we developed a MC model of a CT x-ray tube. The model was validated with half-value layer (HVL) measurements and spectral measurements with a high resolution Schottky CdTe spectrometer. First and second HVL for beams without additional filtration calculated from the MC modelled spectra and determined from attenuation measurements differ by less than 2.5%. The differences between the first and second HVL for both filtered and non-filtered beams calculated from the MC modelled spectra and spectral measurements with the CdTe detector were less than 1.8%. The MC modelled spectra match the directly measured spectra. This works presents a first step towards an accurate MC model of a CT scanner.

[1]  Satoshi Miyajima,et al.  Thin CdTe detector in diagnostic x-ray spectroscopy. , 2003, Medical physics.

[2]  David J Brenner,et al.  Is it time to retire the CTDI for CT quality assurance and dose optimization? , 2005, Medical physics.

[3]  M Yaffe,et al.  Spectroscopy of diagnostic x rays by a Compton-scatter method. , 1976, Medical physics.

[4]  H. Nagel Limitations in the determination of total filtration of x-ray tube assemblies. , 1988, Physics in medicine and biology.

[5]  Koji Maeda,et al.  Compton-scattering measurement of diagnostic x-ray spectrum using high-resolution Schottky CdTe detector. , 2005, Medical physics.

[6]  G Matscheko,et al.  A Compton scattering spectrometer for determining X-ray photon energy spectra. , 1987, Physics in medicine and biology.

[7]  S M Seltzer,et al.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology. , 2001, Medical physics.

[8]  H. Mota,et al.  (HP)Ge Measurement of spectra for diagnostic X-ray beams. , 2004, Radiation protection dosimetry.

[9]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[10]  Diagnostic x-ray spectra: a comparison of spectra generated by different computational methods with a measured spectrum. , 1998, Medical physics.

[11]  J J DeMarco,et al.  A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. , 2005, Physics in medicine and biology.

[12]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[13]  Compton spectroscopy in the diagnostic x-ray energy range. I. Spectrometer design. , 1989, Physics in medicine and biology.

[14]  Stephen M. Seltzer,et al.  Calculated response of intrinsic germanium detectors to narrow beams of photons with energies up to ∼300 keV☆ , 1981 .

[15]  S. Mori,et al.  Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner. , 2006, The British journal of radiology.

[16]  Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra. , 1980, Medical physics.

[17]  F Verhaegen,et al.  Monte Carlo modelling of radiotherapy kV x-ray units. , 1999, Physics in medicine and biology.

[18]  Roland Ribberfors,et al.  Relationship of the relativistic Compton cross section to the momentum distribution of bound electron states , 1975 .

[19]  G. Matscheko,et al.  A Compton scattering spectrometer for determining X-ray photon energy spectra. , 1987, Physics in medicine and biology.