Optical properties of human sclera, and their consequences for transscleral laser applications

The spectral dependence of the optical properties of human sclera adjacent to the limbus was investigated and related to the potentials of transscleral photocoagulation. The total transmission, absorption, and reflection, as well as the angular distribution of the transmitted and reflected light were measured at five laser wavelengths (442 nm, 514 nm, 633 nm, 804 nm, and 1,064 nm), both for noncontact and contact applications. Absorption and scattering coefficients were determined using the Kubelka‐Munk model for light propagation through a scattering tissue. The scleral transmission is only 6% at 442 nm but increases to 35% at 804 nm and to 53% at 1,064 nm. The absorption is high at short wavelengths with 40% at 442 nm but it is only 6% at 804 nm and 1,064 nm. The reflection is generally higher than 40% and shows little wavelength dependence. The transmitted light is scattered diffusely at short wavelengths, but at 804 nm and 1,064 nm it exhibits a fairly narrow angular distribution in forward direction. Fiber contact leads to an increase of transmission, with a factor of 3.5 at 442 nm, of 2.0 at 804 nm, and 1.5 at 1,064 nm. Our results indicate that the diode laser (804 nm) and the Nd:YAG laser (1,064 nm) with contact delivery are best suited for transscleral photocoagulation.

[1]  P. Kubelka,et al.  New Contributions to the Optics of Intensely Light-Scattering Materials. Part I , 1948 .

[2]  D. Maurice,et al.  The Cornea and Sclera , 1962 .

[3]  R S Smith,et al.  Ocular hazards of transscleral laser radiation. I. Spectral reflection and transmission of the sclera, choroid and retina. , 1968, American journal of ophthalmology.

[4]  R S Smith,et al.  Ocular hazards of transscleral laser radiation. II. Intraocular injury produced by ruby and neodymium lasers. , 1969, American journal of ophthalmology.

[5]  G. Benedek,et al.  Theory of transparency of the eye. , 1971, Applied optics.

[6]  George B. Benedek,et al.  Intraocular light Scattering , 1973 .

[7]  Franz Hillenkamp,et al.  Interaction between Laser Radiation and Biological Systems , 1980 .

[8]  John A. Parrish,et al.  Optical Properties of Human Skin , 1982 .

[9]  A. Oseroff,et al.  Preferential light absorption in atheromas in vitro. Implications for laser angioplasty. , 1986, The Journal of clinical investigation.

[10]  G. Trope,et al.  Neodymium: YAG transscleral cyclocoagulation in human eyes. , 1987, Ophthalmology.

[11]  M. B. Shields,et al.  Transscleral neodymium-YAG cyclophotocoagulation. A histologic study of human autopsy eyes. , 1988, Archives of ophthalmology.

[12]  R. Birngruber,et al.  Morphologische Befunde des Kaninchenziliarkörpers nach transskleraler cw-Nd-YAG-Laserkoagulation , 1988 .

[13]  E. Donnenfeld,et al.  Transscleral neodymium:YAG thermal cyclophotocoagulation in refractory glaucoma. A preliminary report. , 1988, Ophthalmology.

[14]  D Royston,et al.  Optical properties of fiber optic surgical tips. , 1989, Applied optics.

[15]  C. Puliafito,et al.  Transscleral cyclophotocoagulation using a contact laser probe: A histologic and clinical study in rabbits , 1989, Lasers in surgery and medicine.

[16]  G. Spaeth,et al.  Neodymium-YAG transscleral cyclophotocoagulation. The role of pigmentation. , 1989, Investigative ophthalmology & visual science.

[17]  J. Federman,et al.  A comparison of CW Nd:YAG contact transscleral cyclophotocoagulation with cyclocryopexy. , 1989, Investigative ophthalmology & visual science.

[18]  G. Trope,et al.  Mid-term effects of neodymium: YAG transscleral cyclocoagulation in glaucoma. , 1990, Ophthalmology.

[19]  G. Peyman,et al.  Transscleral application of a semiconductor diode laser , 1990, Lasers in surgery and medicine.

[20]  J. Schuman,et al.  Experimental use of semiconductor diode laser in contact transscleral cyclophotocoagulation in rabbits. , 1990, Archives of ophthalmology.

[21]  J. Schuman,et al.  Contact transscleral continuous wave neodymium:YAG laser cyclophotocoagulation. , 1990, Ophthalmology.

[22]  M. B. Shields,et al.  Comparison of transscleral neodymium:YAG cyclophotocoagulation with and without a contact lens in human autopsy eyes. , 1990, American journal of ophthalmology.

[23]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .