Microfabricated On-Line Sensor for Continuous Monitoring of l-Glutamate

An on-line sensor was developed by using a micro-machining technique for the continuous measurement of extracellular glutamate. The sensor was made by bonding two glass plates together. One of the plates has a rectangular flow channel which is connected to both a sampling and an outlet capillary. The other has a carbon film-based electrochemical cell, which consists of an enzyme-modified electrode surrounded by polymer film to form a thin-layer-channel flow cell. The sensor has a high analyte conversion efficiency due to the cell structure. As a result, we obtained a low detection limit of 44 nM ( S/N= 3) . The cathodic current started to increase about 10 s after sample introduction at a flow rate of 2 μl/min due to its small inner volume. Using the sensor, we can monitor the extracellular L -glutamate increase caused by stimulating it with KC1 and 7-aminobutyric acid (GABA) by locating the sampling capillary very close to the cell.

[1]  K. Torimitsu,et al.  On-line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue. , 1998, Analytical chemistry.

[2]  R. Kennedy,et al.  High temporal resolution monitoring of glutamate and aspartate in vivo using microdialysis on-line with capillary electrophoresis with laser-induced fluorescence detection. , 1997, Analytical chemistry.

[3]  L. Parisi,et al.  Microdialysis monitoring of extracellular glutamate combined with the simultaneous recording of evoked field potentials in hippocampal organotypic slice cultures , 1997, Journal of Neuroscience Methods.

[4]  K. Torimitsu,et al.  Real‐time detection of GABA‐induced synaptic glutamate release in cultured rat cortex , 1997, Neuroreport.

[5]  S. Cosnier,et al.  An electrochemical method for making enzyme microsensors. Application to the detection of dopamine and glutamate. , 1997, Analytical chemistry.

[6]  M. A. Northrup,et al.  Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. , 1996, Analytical chemistry.

[7]  Andrew G. Ewing,et al.  Continuous Separations with Microfabricated Electrophoresis−Electrochemical Array Detection , 1996 .

[8]  P. Osborne,et al.  Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor. , 1996, Analytical chemistry.

[9]  T. P. Obrenovitch,et al.  Extracellular glutamate: on-line monitoring using microdialysis coupled to enzyme-amperometric analysis , 1995, Journal of Neuroscience Methods.

[10]  S. Lunte,et al.  Continuous in vivo monitoring of amino acid neurotransmitters by microdialysis sampling with on-line derivatization and capillary electrophoresis separation. , 1995, Analytical chemistry.

[11]  G. S. Wilson,et al.  Direct measurement of glutamate release in the brain using a dual enzyme-based electrochemical sensor , 1994, Brain Research.

[12]  L. Symon,et al.  Extracellular Glutamate During Focal Cerebral Ischaemia in Rats: Time Course and Calcium Dependency , 1994, Journal of neurochemistry.

[13]  M. Fillenz,et al.  On-line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode. , 1994, Analytical chemistry.

[14]  S. Jacobson,et al.  High-Speed Separations on a Microchip , 1994 .

[15]  A. Koshy,et al.  Amperometric Biosensors for On-Line Monitoring of Extracellular Glucose and Glutamate in the Brain , 1994 .

[16]  O. Niwa,et al.  Voltammetric measurements of reversible and quasi-reversible redox species using carbon film based interdigitated array microelectrodes , 1994 .

[17]  Kenji Yokoyama,et al.  Integration of enzyme-immobilized column with electrochemical flow cell using micromachining techniques for a glucose detection system , 1993 .

[18]  W. Kuhr,et al.  Dehydrogenase-modified carbon-fiber microelectrodes for the measurement of neurotransmitter dynamics. 1. NADH voltammetry. , 1993, Analytical chemistry.

[19]  Isao Karube,et al.  Ultra micro glutamate sensor using platinized carbon-fiber electrode and integrated counter electrode , 1993 .

[20]  T. Bliss,et al.  A synaptic model of memory: long-term potentiation in the hippocampus , 1993, Nature.

[21]  O. Niwa,et al.  Fabrication and electrochemical features of new carbon based interdigitated array microelectrodes , 1992 .

[22]  D. J. Harrison,et al.  Capillary electrophoresis and sample injection systems integrated on a planar glass chip , 1992 .

[23]  D. J. Harrison,et al.  Planar chips technology for miniaturization and integration of separation techniques into monitoring systems. Capillary electrophoresis on a chip , 1992 .

[24]  Shuichi Shoji,et al.  Prototype miniature blood gas analyser fabricated on a silicon wafer , 1988 .

[25]  Masao Ito Long-term depression as a memory process in the cerebellum , 1986, Neuroscience Research.

[26]  T. Bliss,et al.  Correlation between long‐term potentiation and release of endogenous amino acids from dentate gyrus of anaesthetized rats. , 1986, The Journal of physiology.

[27]  H. Benveniste,et al.  Elevation of the Extracellular Concentrations of Glutamate and Aspartate in Rat Hippocampus During Transient Cerebral Ischemia Monitored by Intracerebral Microdialysis , 1984, Journal of neurochemistry.

[28]  Masao Ito,et al.  Climbing fibre induced depression of both mossy fibre responsiveness and glutamate sensitivity of cerebellar Purkinje cells , 1982, The Journal of physiology.

[29]  Tsutomu Horiuchi,et al.  Small-Volume On-Line Sensor for Continuous Measurement of γ-Aminobutyric Acid , 1998 .

[30]  K. Torimitsu,et al.  Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro-capillary sampling. , 1997, Biosensors & bioelectronics.

[31]  G Jobst,et al.  Miniaturized thin film glutamate and glutamine biosensors. , 1995, Biosensors & bioelectronics.

[32]  Adam Heller,et al.  Applications of “Wired” Peroxidase Electrodes for Peroxide Determination in Liquid Chromatography Coupled to Oxidase Immobilized Enzyme Reactors , 1995 .

[33]  A. Heller,et al.  Hydrogen peroxide and .beta.-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a three-dimensional electron relaying polymer network , 1992 .

[34]  Martyn G. Boutelle,et al.  The dialysis electrode—a new method for in vivo monitoring , 1992 .

[35]  Albert van den Berg,et al.  A silicon integrated miniature chemical analysis system , 1992 .

[36]  T. Robinson,et al.  Microdialysis in the neurosciences , 1991 .

[37]  D. Nikolelis Kinetic-potentiometric determination of monosodium glutamate in soups and soup bases and of glutamic dehydrogenase. , 1987, The Analyst.

[38]  Lo Gorton,et al.  Enzyme Electrodes For L-Glutamate Using Chemical Redox Mediators and Enzymatic Substrate Amplification , 1986 .

[39]  A. Sibbald,et al.  A miniature flow-through cell with a four-function chemfet integrated circuit for simultaneous measurements of potassium, hydrogen, calcium and sodium ions , 1984 .