Reduced Wear with Oxidized Zirconium Femoral Heads

Wear-related complications have been a major cause of revisions and reoperations following total hip arthroplasty. In the past, several materials have shown promise for reducing polyethylene wear, but they have draw-backs. Elimination of polyethylene from prosthetic designs has not gained wide acceptance because it limits design flexibility and introduces other risks: fractures with ceramic-on-ceramic bearings and metal-ion release with metal-on-metal bearings1,2. In an attempt to address the problem on the femoral side, opposite the polyethylene, ceramic modular heads were introduced because their surfaces are more abrasion-resistant and produce less friction than do metal surfaces, thereby reducing abrasive and adhesive wear of the polyethylene3. The use of oxide ceramics for the articulating femoral head can reduce wear by 25% to 50%4-6. However, ceramics such as monolithic zirconia and alumina are susceptible to brittle fracture, with the need for immediate revision1. On the acetabular side, highly crosslinked ultra-high molecular weight polyethylene was used for liners more than thirty years ago7-9. This practice was ended after a brief time because of commercial considerations, but subsequent clinical results have indicated that these liners undergo substantially less wear than do conventional ultra-high molecular weight polyethylene liners. Recently, manufacturers have introduced new highly crosslinked ultra-high molecular weight polyethylene acetabular liners, which also offer the potential of reducing wear10,11. However, laboratory results have indicated that the relative advantage of such polyethylene can be reduced when it articulates against rougher surfaces12. Metallic cobalt-chromium (CoCr) femoral heads do not have the same risk of fracture as ceramic heads, but their surfaces become roughened as a result of abrasive and oxidative wear3. Evidence of this roughening can be seen on retrieved heads, and both clinical and …

[1]  D Dowson,et al.  Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. , 1996, The Journal of bone and joint surgery. British volume.

[2]  C. Engh,et al.  Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem* , 1996, The Journal of bone and joint surgery. American volume.

[3]  T. Bauer,et al.  New Polys for Old: Contribution or Caveat? , 2001, Journal of Bone and Joint Surgery. American volume.

[4]  J. Fisher,et al.  Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  N. Baldini,et al.  Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. , 2002, Journal of biomedical materials research.

[6]  A Unsworth,et al.  The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets. , 1997, Medical engineering & physics.

[7]  M. Ries,et al.  Polyethylene Wear Performance of Oxidized Zirconium and Cobalt-Chromium Knee Components Under Abrasive Conditions , 2002, The Journal of bone and joint surgery. American volume.

[8]  M. Ries,et al.  Relationship Between Gravimetric Wear and Particle Generation in Hip Simulators: Conventional Compared with Cross-Linked Polyethylene , 2001, The Journal of bone and joint surgery. American volume.

[9]  R. Barrack,et al.  Analysis of retrieved uncemented porous-coated acetabular components in patients with and without pelvic osteolysis. , 2002, Orthopedics.

[10]  B M Wroblewski,et al.  Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. , 1999, The Journal of bone and joint surgery. British volume.

[11]  J. Davidson,et al.  Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. , 1993, Clinical orthopaedics and related research.

[12]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[13]  W H Harris,et al.  Surface damage to cobalt-chrome femoral head prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[14]  H. Oonishi,et al.  Wear of high-dose gamma-irradiated polyethylene in total hip replacements , 2000, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[15]  B M Wroblewski,et al.  Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report. , 2005, The Journal of bone and joint surgery. British volume.