Improved D-StatCom control for operation with unbalanced currents and voltages

This paper presents a new D-StatCom control algorithm which enables separate control of positive- and negative-sequence currents and decoupled control of d- and q-axes current components. The algorithm is based on the developed mathematical model in the d-q coordinates for a D-StatCom operating under unbalanced conditions. The problem of dc-side voltage ripple and ac-side harmonics generation due to unbalanced voltages/currents is solved by using switching function modulation, enabling the use of a relatively small capacitor on the dc side. The control algorithm is also suitable for high-power applications using multipulse voltage-source converters. The algorithm is tested by means of detailed simulation using PSCAD, where the performance is validated in the case of severe network fault and in the case of unbalanced load compensation. The compensator voltages are generated by means of pulsewidth modulation.

[1]  Ying Jiang,et al.  General analysis of harmonic transfer through converters , 1997 .

[2]  Aniruddha M. Gole,et al.  Steady state frequency response of STATCOM , 2001 .

[3]  G. D. Marques,et al.  An active power filter and unbalanced current compensator , 1997, IEEE Trans. Ind. Electron..

[4]  Kamal Al-Haddad,et al.  An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads , 2000 .

[5]  Robert H. Lasseter,et al.  Statcom controls for operation with unbalanced voltages , 1998 .

[6]  Mauricio Aredes,et al.  Multi-pulse STATCOM operation under unbalanced voltages , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[7]  A. Sonnenmoser,et al.  Line current balancing with a unified power flow controller , 1999 .

[8]  Igor Papic,et al.  UPFC converter-level control system using internally calculated system quantities for decoupling , 2003 .

[9]  Yuan-Yih Hsu,et al.  A novel approach to the design of a shunt active filter for an unbalanced three-phase four-wire system under nonsinusoidal conditions , 2000 .

[10]  Paolo Mattavelli,et al.  An adaptive controller in stationary reference frame for D-statcom in unbalanced operation , 2004, IEEE Transactions on Industrial Electronics.

[11]  P. Enjeti,et al.  A new technique to reject DC-link voltage ripple for inverters operating on programmed PWM waveforms , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[12]  A. Ekstrom,et al.  Applying PWM to control overcurrents at unbalanced faults of forced-commutated VSCs used as static VAr compensators , 1997 .

[13]  Igor Papic Mathematical analysis of FACTS devices based on a voltage source converter: Part II: steady state operational characteristics , 2000 .

[14]  Arindam Ghosh,et al.  A new approach to load balancing and power factor correction in power distribution system , 2000 .

[15]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[16]  I. Papič Mathematical analysis of FACTS devices based on a voltage source converter , 2000 .