The Influence of Speed During Stripping in Descemet Membrane Endothelial Keratoplasty Tissue Preparation.

PURPOSE To evaluate whether the speed of stripping a Descemet membrane endothelial keratoplasty graft influences the graft scroll width. METHODS Human corneas suitable for research were selected for the study. Pairs of corneas were randomly divided into 2 groups: 1 cornea was stripped with a slow speed (group 1) and the contralateral with a fast speed (group 2). Slow speed was defined as the total time greater than 150 seconds or speed <0.057 mm/s. Fast peeling was defined as less than 75 seconds or speed >0.11 mm/s. The grafts acquired were evaluated by microscopy for the graft scroll width and endothelial cell density change pre- and post-preparation. RESULTS Twenty corneas of 10 donors were included in the analysis. The mean donor age was 68.6 ± 7.58 years. The mean total time of the tissue preparation in group 1 was 282.7 ± 28 seconds and in group 2 was 126 ± 50 seconds (P-value = 0.00000047). The mean speed of stripping in group 1 was 0.045 ± 0.006 mm/s and in group 2 was 0.266 ± 0.093 mm/s (P-value = 0.000027). The graft width in group 1 was 6.4 ± 0.92 mm and in group 2 was 2.87 ± 0.32 mm (P-value = 0.00000014). The mean endothelial cell loss in group 1 was 389 ± 149 cells/mm and in group 2 was 186 ± 63.44 cells/mm (P-value = 0.00134). CONCLUSION We found a correlation between the speed of stripping, scroll width, and endothelial cell loss. Slow-peeled Descemet membrane endothelial keratoplasty grafts result in a wider scroll width but were associated with a greater reduction in endothelial cell density.

[1]  S. Oellerich,et al.  Parameters associated with endothelial cell density variability after Descemet membrane endothelial keratoplasty. , 2020, American journal of ophthalmology.

[2]  Justis P. Ehlers,et al.  Intraoperative Optical Coherence Tomography-Assisted Descemet Membrane Endothelial Keratoplasty in the DISCOVER Study: First 100 Cases. , 2020, American journal of ophthalmology.

[3]  D. Dobrowolski,et al.  Changes in the Density of Corneal Endothelial Cells in Elderly Diabetic Patients After Combined Phacovitrectomy and Ex-PRESS Glaucoma 
Implants , 2019, Current pharmaceutical biotechnology.

[4]  D. Gatinel,et al.  C-Press Technique to Facilitate Descemet Membrane Endothelial Keratoplasty Surgery in Vitrectomized Patients: A Case Series. , 2019, Cornea.

[5]  S. Jabbour,et al.  The role of novel DMEK graft shapes in facilitating intraoperative unscrolling , 2018, Graefe's Archive for Clinical and Experimental Ophthalmology.

[6]  P. Gain,et al.  Endothelial quality of eye bank-prestripped DMEK prepared form organ-cultured corneas with the Muraine technique , 2018, Cell and Tissue Banking.

[7]  K. Bartz-Schmidt,et al.  Novel Technique for Improving Graft Unfolding in Vitrectomized Eyes Using a Temporary Diaphragm in Descemet Membrane Endothelial Keratoplasty , 2018, Cornea.

[8]  S. Ferrari,et al.  Descemet Membrane Endothelial Keratoplasty Learning Curve for Graft Preparation in an Eye Bank Using 645 Donor Corneas , 2018, Cornea.

[9]  J. A. Gomes,et al.  Descemet's membrane endothelial keratoplasty with a simplified technique and low complication rate: the samba technique. , 2018, Arquivos brasileiros de oftalmologia.

[10]  A. Shortt,et al.  Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure. , 2016, The Cochrane database of systematic reviews.

[11]  Ting Huang,et al.  Efficacy and safety of Descemet’s membrane endothelial keratoplasty versus Descemet’s stripping endothelial keratoplasty: A systematic review and meta-analysis , 2017, PloS one.

[12]  Z. Krūmiņa,et al.  Importance of Axial Length and Functional Corneal Endothelial Cells in Descemet Membrane Endothelial Keratoplasty. , 2017, Cornea.

[13]  S. Ferrari,et al.  Comparison of preservation and transportation protocols for preloaded Descemet membrane endothelial keratoplasty , 2017, British Journal of Ophthalmology.

[14]  W. Feuer,et al.  Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft , 2017, Clinical ophthalmology.

[15]  Z. M. Mayko,et al.  Relationship Between Tissue Unscrolling Time and Endothelial Cell Loss , 2016, Cornea.

[16]  W. Sekundo,et al.  A simple rescue maneuver for unfolding and centering a tightly rolled graft in Descemet membrane endothelial keratoplasty , 2014, Clinical ophthalmology.

[17]  D. Böhringer,et al.  Influence of Donor Characteristics on Descemet Membrane Endothelial Keratoplasty , 2014, Cornea.

[18]  F. Price,et al.  Evolution of Endothelial Keratoplasty , 2013, Cornea.

[19]  Y. Khalifa,et al.  Descemet membrane endothelial keratoplasty: why does the donor tissue roll? , 2013, Cornea.