FDTD simulation of direct lightning strike to a phase conductor: Influence of corona on transient voltages at the tower

Abstract In this paper, a simplified model of corona discharge for the finite-difference time-domain (FDTD) computations has been applied to analysis of transient voltages at the tower of a transmission line caused by direct lightning strikes to an upper phase conductor. In the simulations, three 40-m towers, separated by 300 m, with one overhead ground wire and three phase conductors are employed. Corona is assumed to occur only on the upper phase conductor struck by lightning. The progression of corona streamers from the conductor is represented as the radial expansion of cylindrical conducting region around the conductor. The reduction of transient-voltage peak due to corona is not very significant, so that the voltage at the nearest tower exceeds the insulation level of 66/77 kV power line considered in this paper. For a 10-kA peak current, the upper-phase-conductor voltage peaks are reduced by 26% and 21% for a positive stroke with 1-μs- and 3-μs-risetime currents, respectively, and those for negative-stroke case are reduced by 18% and 13%, respectively. For a 20-kA peak current, the corresponding upper-phase-voltage peaks are reduced by 32% and 25% for the positive-stroke case, and those for the negative-stroke case are reduced by 22% and 15%.

[1]  Tran Huu Thang,et al.  FDTD Simulation of Lightning Surges on Overhead Wires in the Presence of Corona Discharge , 2012, IEEE Transactions on Electromagnetic Compatibility.

[2]  Taku Noda,et al.  Charge-Voltage curves of surge corona on transmission lines: two measurement methods , 2003 .

[3]  C. F. Wagner,et al.  High-Voltage Impulse Tests on Transmission Lines [includes discussion] , 1954, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[4]  Gildas Hartmann,et al.  Theoretical Evaluation of Peek's Law , 1984, IEEE Transactions on Industry Applications.

[5]  Tran Huu Thang,et al.  FDTD Simulation of Insulator Voltages at a Lightning-Struck Tower Considering Ground-Wire Corona , 2013, IEEE Transactions on Power Delivery.

[6]  野田 琢,et al.  Development of a transmission-line model considering the skin and corona effects for power systems transient analysis , 1997 .

[7]  Vernon Cooray,et al.  The lightning flash , 2003 .

[8]  K. Yee Numerical solution of initial boundary value problems involving maxwell's equations in isotropic media , 1966 .

[9]  Alex Guenther,et al.  Seasonal variation of biogenic VOC emissions above a mixed hardwood forest in northern Michigan , 2003 .

[10]  Tran Huu Thang,et al.  A Simplified Model of Corona Discharge on Overhead Wire for FDTD Computations , 2012, IEEE Transactions on Electromagnetic Compatibility.

[11]  Vladimir A. Rakov,et al.  Applications of the FDTD Method to Lightning Electromagnetic Pulse and Surge Simulations , 2014, IEEE Transactions on Electromagnetic Compatibility.

[12]  S. Yokoyama,et al.  Thin Wire Representation in Finite Difference Time Domain Surge Simulation , 2002, IEEE Power Engineering Review.

[13]  Yoshihiro Baba,et al.  On the transmission line model for lightning return stroke representation , 2003 .