Development of a Scheimpflug slit lamp camera system for quantitative densitometric analysis

We have developed a computerised video system for accurate quantification of lens opacities from Scheimpflug images. Using a modified Zeiss Scheimpflug camera and Macintosh computer, the system software can warn of improper exposure and can provide immediate results of cataract progression on individual patients. These results are obtained from a novel technique which automatically divides the lens into anatomical regions and computes regional densities in the standard optical density unit. Because of the system's speed, the operator can properly capture and analyse a cataract in seconds, compare results with past patient records and give feedback to the patient on the results of the analysis. The system provides the appropriate data integrity and formats for documenting and monitoring lens opacities. Such a system will be useful in longitudinal studies of cataracts (i.e. for natural history and anti-cataract drug trials).

[1]  M. Unser,et al.  Computerized cataract detection and classification. , 1990, Current eye research.

[2]  R Weale The Oqual: a new device for measuring the optical quality of the anterior segment of the human eye. , 1992, Experimental eye research.

[3]  N. Brown An advanced slit-image camera. , 1972, The British journal of ophthalmology.

[4]  B L Trus,et al.  In vivo studies on cataracts using the Scheimpflug slit lamp camera. , 1987, Investigative ophthalmology & visual science.

[5]  M. C. Leske,et al.  The Lens Opacities Classification System III , 1993 .

[6]  P. Niesel Spaltlampenphotographie mit der Haag-Streit-Spaltlampe 900 , 1966 .

[7]  Nicholas A P Brown,et al.  The objective assessment of cataract , 1987, Eye.

[8]  R. Lowy,et al.  Chapter 15 Characteristics of Low Light Level Television Cameras , 1988 .

[9]  R. C. Drews,et al.  Depth of Field in Slit Lamp Photography , 1964 .

[10]  R A Weale,et al.  New method for visualising discontinuities in the crystalline lens. , 1986, The British journal of ophthalmology.

[11]  S. Duke-Elder Textbook of Ophthalmology , 1950 .

[12]  London,et al.  Clinical Ophthalmology. Vol. 2 , 1971 .

[13]  L T Chylack,et al.  Lens opacities classification system II (LOCS II) , 1989, Archives of ophthalmology.

[14]  John M Sparrow,et al.  The Oxford modular cataract image analysis system , 1990, Eye.

[15]  R. Lowy,et al.  Characteristics of low light level television cameras. , 1989, Methods in cell biology.

[16]  A. Findlay Practical physical chemistry , 1919 .

[17]  H. Laser,et al.  Measuring lens transparency by scheimpflug photography of the anterior eye segment: principle, instrumentation, and application to clinical and experimental ophthalmology , 1987 .

[18]  R. Weale,et al.  The Senescence of Human Vision , 1992 .

[19]  V. Dragomirescu,et al.  Development of a New Equipment for Rotating Slit Image Photography According to Scheimpflug’s Principle , 1978 .

[20]  M. Unser,et al.  Aging Studies on Normal Lens Using the Scheimpflug Slit-lamp Camera , 2022 .

[21]  N. Brown Slit-image photography. , 1970, Transactions of the ophthalmological societies of the United Kingdom.

[22]  W. Lohmann,et al.  Device for measuring native fluorescence of lenses. , 1988, Journal of biochemical and biophysical methods.