Capacitive multi-electrode array with real-time electrode selection for unobtrusive ECG & BIOZ monitoring

Capacitively-coupled ECG (ccECG) and bioimpedance (ccBIOZ) measurements are highly sensitive to motion artefacts. This limits their use in real-life situations. This work presents an array-based system for the simultaneous acquisition of ccECG and ccBIOZ, together with a quality-based electrode scanning approach for ccECG. This allows to increase the time coverage of contactless measurements in real-life situations and reduces the impact of artefacts. This solution was evaluated on a car seat and a mattress prototype. Results show the benefit of this combined array and algorithm approach: for every body position the algorithm was able to find more than one electrode combination providing high-quality ccECG. Night-long recordings were also performed, resulting in a mean time coverage of 72.5%.

[1]  R Vullings,et al.  Unobtrusive ECG monitoring in the NICU using a capacitive sensing array , 2014, Physiological measurement.

[2]  Oliver Amft,et al.  Reducing motion artifacts for robust QRS detection in capacitive sensor arrays , 2011, ISABEL '11.

[3]  Pieter Harpe,et al.  Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering , 2019, IEEE Transactions on Instrumentation and Measurement.

[4]  Steffen Leonhardt,et al.  Triboelectricity in Capacitive Biopotential Measurements , 2011, IEEE Transactions on Biomedical Engineering.

[5]  Refet Firat Yazicioglu,et al.  A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSP , 2015, IEEE Journal of Solid-State Circuits.

[6]  Stephan Heuer,et al.  Motion Artefacts in Capacitively Coupled ECG Electrodes , 2009 .

[7]  Geert Langereis,et al.  Contactless EMG sensors embroidered onto textile , 2007, BSN.

[8]  Refet Firat Yazicioglu,et al.  Noncontact ECG Recording System With Real Time Capacitance Measurement for Motion Artifact Reduction , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[9]  Xiong Yu,et al.  Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review , 2016, IEEE Sensors Journal.

[10]  Chris Van Hoof,et al.  Robust wireless capacitive ECG system with adaptive signal quality and motion artifact reduction , 2016, 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[11]  Danny Abad,et al.  Development of a capacitive bioimpedance measurement system , 2009 .

[12]  Steffen Leonhardt,et al.  ECG on the Road: Robust and Unobtrusive Estimation of Heart Rate , 2011, IEEE Transactions on Biomedical Engineering.