RESPIRE: A Spectral Kurtosis-Based Method to Extract Respiration Rate from Wearable PPG Signals

In this paper, we present the design of a wearable photoplethysmography (PPG) system, R-band for acquiring the PPG signals. PPG signals are influenced by the respiration or breathing process and hence can be used for estimation of respiration rate. R-Band detects the PPG signal that is routed to a Bluetooth low energy device such as a nearbyplaced smartphone via microprocessor. Further, we developed an algorithm based on Extreme Learning Machine (ELM) regression for the estimation of respiration rate. We proposed spectral kurtosis features that are fused with the state-of the-art respiratory-induced amplitude, intensity and frequency variations-based features for the estimation of respiration rate (in units of breaths per minute). In contrast to the neural network (NN), ELM does not require tuning of hidden layer parameter and thus drastically reduces the computational cost as compared to NN trained by the standard backpropagation algorithm. We evaluated the proposed algorithm on Capnobase data available in the public domain.

[1]  Mark E Kunik,et al.  Surprisingly high prevalence of anxiety and depression in chronic breathing disorders. , 2005, Chest.

[2]  M. Fine,et al.  Does this patient have community-acquired pneumonia? Diagnosing pneumonia by history and physical examination. , 1997, JAMA.

[3]  V. Mohsenin,et al.  Sleep-Related Breathing Disorders and Risk of Stroke , 2001, Stroke.

[4]  R. Cohen,et al.  An Efficient Algorithm for Spectral Analysis of Heart Rate Variability , 1986, IEEE Transactions on Biomedical Engineering.

[5]  Robert B. Randall,et al.  The spectral kurtosis: application to the vibratory surveillance and diagnostics of rotating machines , 2006 .

[6]  A. J. Bernheim Brush,et al.  Health chair: implicitly sensing heart and respiratory rate , 2014, UbiComp.

[7]  Mark D. Huffman,et al.  Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association , 2016, Circulation.

[8]  Nyein Nyein Lwin,et al.  Pneumonia: the forgotten killer of children. , 2006 .

[9]  Daniel J Buysse,et al.  Sleep–Related Breathing Disorders in Adults: Recommendations for Syndrome Definition and Measurement Techniques in Clinical Research , 2000 .

[10]  Harishchandra Dubey,et al.  EchoWear: smartwatch technology for voice and speech treatments of patients with Parkinson's disease , 2015, Wireless Health.

[11]  Walter Karlen,et al.  Multiparameter Respiratory Rate Estimation From the Photoplethysmogram , 2013, IEEE Transactions on Biomedical Engineering.

[12]  Xiang Chen,et al.  Comparison of respiratory-induced variations in photoplethysmographic signals , 2010, Physiological measurement.

[13]  A. Johansson Neural network for photoplethysmographic respiratory rate monitoring , 2003, Medical and Biological Engineering and Computing.

[14]  Chee Kheong Siew,et al.  Extreme learning machine: Theory and applications , 2006, Neurocomputing.

[15]  Stuart F. Quan,et al.  New definitions of sleep disordered breathing - Not yet a mandate for change in clinical practice , 1999 .

[16]  John G. Webster,et al.  Design of Pulse Oximeters , 1997 .

[17]  W. Karlen,et al.  Development of a Screening Tool for Sleep Disordered Breathing in Children Using the Phone Oximeter™ , 2014, PloS one.

[18]  Ramdas Kumaresan,et al.  Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts , 2016, Journal of Ambient Intelligence and Humanized Computing.

[19]  T. Tamura,et al.  Photoplethysmographic measurement of heart and respiratory rates using digital filters , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[20]  A. Buda,et al.  Effect of intrathoracic pressure on left ventricular performance. , 1979, The New England journal of medicine.

[21]  Harishchandra Dubey,et al.  BigEAR: Inferring the Ambient and Emotional Correlates from Smartphone-Based Acoustic Big Data , 2016, 2016 IEEE First International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE).

[22]  Walter Karlen,et al.  Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  Walter Karlen,et al.  Respiratory rate assessment from photoplethysmographic imaging , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  Guy A. Dumont,et al.  Correction: Improving the Accuracy and Efficiency of Respiratory Rate Measurements in Children Using Mobile Devices , 2015, PloS one.

[25]  Mark D. Huffman,et al.  AHA Statistical Update Heart Disease and Stroke Statistics — 2012 Update A Report From the American Heart Association WRITING GROUP MEMBERS , 2010 .

[26]  Paris B Lovett,et al.  The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. , 2005, Annals of emergency medicine.

[27]  J. Antoni The spectral kurtosis: a useful tool for characterising non-stationary signals , 2006 .

[28]  J. N. Watson,et al.  Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study , 2012, Journal of Clinical Monitoring and Computing.

[29]  Qing Yang,et al.  Fog Data: Enhancing Telehealth Big Data Through Fog Computing , 2015, ASE BD&SI.