Improvement of Recloser-Fuse Operations and Coordination in a Power Distribution System With SFCL

In this paper, we describes how to coordinate between recloser and fuse in power distribution system with superconducting fault current limiters (SFCL). The recloser and fuses are the main overcurrent protective devices in power distribution system. Universally, to protect against permanent faults, fuses are installed on overhead feeder laterals and the reclosers as a backup protection against temporary faults remove many unnecessary outages. Here, the recloser is set to trip using TCC curve for a temporary fault before any of the fuses can melt. If the fault is a permanent fault, the fuse has to melt just before the last delay trip of the recloser. However, the application of a resistive SFCL in power distribution system affects the recloser-fuse operation and coordination as decreased fault currents. In case that when a permanent fault occurs, the recloser could be locked-out after the last delay trip before the fuses operate. Therefore, to solve these cases, we performed experiments which are the recloser-fuse operation and coordination in the modeled power distribution system with the SFCL. Based on the experimental verification, we improved to coordinate the recloser-fuse in power distribution system with SFCL.

[1]  Yu Jiang,et al.  Comparison of superconducting fault current limiter in power system , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[2]  Jae Young Yoon,et al.  A Study on SFCL Systems for Korean Power System Application , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[3]  Seong-Woo Yim,et al.  Introduction of a Hybrid SFCL in KEPCO Grid and Local Points at Issue , 2009, IEEE Transactions on Applied Superconductivity.

[4]  I.S. Oh,et al.  Design and Experiments of Novel Hybrid Type Superconducting Fault Current Limiters , 2008, IEEE Transactions on Applied Superconductivity.

[5]  Liangzhen Lin,et al.  Application studies of superconducting fault current limiters in electric power systems , 2002 .

[6]  S. Santoso,et al.  Identification of Fuse and Recloser Operations in a Radial Distribution System , 2007, IEEE Transactions on Power Delivery.

[7]  Sung-Hun Lim Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding , 2008 .

[8]  A. J. Power An overview of transmission fault current limiters , 1995 .

[9]  Lin Ye,et al.  System Studies of the Superconducting Fault Current Limiter in Electrical Distribution Grids , 2007, IEEE Transactions on Applied Superconductivity.

[10]  Sung-Hun Lim Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs , 2007 .

[11]  S. Kalsi,et al.  HTS fault current limiter concept , 2004, IEEE Power Engineering Society General Meeting, 2004..

[12]  J C Kim,et al.  Method of Recloser-Fuse Coordination in a Power Distribution System With Superconducting Fault Current Limiter , 2010, IEEE Transactions on Applied Superconductivity.

[13]  M. Runde,et al.  Assessment study of superconducting fault-current limiters operating at 77 K , 1992 .

[14]  Turan Gonen,et al.  Electric power distribution system engineering , 1985 .

[15]  I.S. Oh,et al.  Practical Application Issues of Superconducting Fault Current Limiters for Electric Power Systems , 2008, IEEE Transactions on Applied Superconductivity.