Bismuth‐Coated Screen‐Printed Electrodes for Stripping Voltammetric Measurements of Trace Lead

Bismuth-coated screen-printed carbon electrodes offer reliable quantitation of trace lead in connection to anodic stripping voltammetry. Such use of bismuth films (instead of mercury coatings) does not affect the reliability of stripping measurements of trace lead. The influence of various experimental variables upon the stripping lead signal at the bismuth-coated thick-film sensor is explored. The square-wave voltammetric stripping response is highly linear over the 10–100 ppb lead range examined (2 min deposition), with a detection limit of 0.3 ppb (10 min deposition) and good precision (RSD=7.4 % at 20 ppb lead). The rapid square-wave stripping voltammetric mode facilitates the use of nondeaerated samples. Applicability to drinking water samples is demonstrated. The attractive behavior of the new disposable “mercury-free” carbon strip electrodes, coupled with the negligible toxicity of bismuth, hold great promise for “one-shot” decentralized lead testing (including blood lead screening).

[1]  Joseph Wang,et al.  Bismuth film electrodes for adsorptive stripping voltammetry of trace nickel , 2000 .

[2]  John P. Hart,et al.  Screen‐printed voltammetric and amperometric electrochemical sensors for decentralized testing , 1994 .

[3]  Samuel P. Kounaves,et al.  Microfabricated Array of Iridium Microdisks as a Substrate for Direct Determination of Cu2+ or Hg2+ Using Square-Wave Anodic Stripping Voltammetry , 1999 .

[4]  Joseph Wang,et al.  Screen-printed stripping voltammetric/potentiometric electrodes for decentralized testing of trace lead , 1992 .

[5]  Khris B. Olsen,et al.  Stripping analysis into the 21st century: faster, smaller, cheaper, simpler and better , 1999 .

[6]  Yudong Wang,et al.  Simplified stripping potentiometry methodology: Application to the determination of lead in wine , 1993 .

[7]  J Wang,et al.  Hand-held lead analyzer. , 2000, Talanta.

[8]  P. Sadler,et al.  Interactions of Bismuth Complexes with Metallothionein(II)* , 1999, The Journal of Biological Chemistry.

[9]  J Wang,et al.  Mercury-free disposable lead sensors based on potentiometric stripping analysis at gold-coated screen-printed electrodes. , 1993, Analytical chemistry.

[10]  R. Boeckx Lead poisoning in children. , 1986, Analytical Chemistry.

[11]  V. Rodilla,et al.  Exposure of cultured human proximal tubular cells to cadmium, mercury, zinc and bismuth: toxicity and metallothionein induction. , 1998, Chemico-biological interactions.

[12]  J. Osterloh,et al.  Indium as internal standard in square wave anodic stripping analysis of lead in blood with microelectrode arrays. , 1997, Analytical chemistry.

[13]  Joseph Wang,et al.  Screen-printed ultramicroelectrode arrays for on-site stripping measurements of trace metals , 1993 .