Highly accelerated vessel‐selective arterial spin labeling angiography using sparsity and smoothness constraints

Purpose To demonstrate that vessel-selectivity in arterial spin labeling angiography can be achieved without any scan time penalty or noticeable loss of image quality compared to conventional arterial spin labeling angiography. Methods Simulations on a numerical phantom were used to assess whether the increased sparsity of vessel-encoded angiograms compared to non-vessel-encoded angiograms alone can improve reconstruction results in a compressed sensing framework. Further simulations were performed to study whether the difference in relative sparsity between non-selective and vessel-selective dynamic angiograms were sufficient to achieve similar image quality at matched scan times in the presence of noise. Finally, data were acquired from 5 healthy volunteers to validate the technique in vivo. All data, both simulated and in vivo, were sampled in 2D using a golden angle radial trajectory and reconstructed by enforcing both image domain sparsity and temporal smoothness on the angiograms in a parallel imaging and compressed sensing framework. Results Relative sparsity was established as a primary factor governing the reconstruction fidelity. Using the proposed reconstruction scheme, differences between vessel-selective and non-selective angiography were negligible compared to the dominant factor of total scan time in both simulations and in vivo experiments at acceleration factors up to R = 34. The reconstruction quality was not heavily dependent on hand-tuning the parameters of the reconstruction. Conclusion The increase in relative sparsity of vessel-selective angiograms compared to non-selective angiograms can be leveraged to achieve higher acceleration without loss of image quality, resulting in the acquisition of vessel-selective information at no scan time cost.

[1]  Hugo R. Shi,et al.  Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity , 2005, IEEE Transactions on Signal Processing.

[2]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..

[3]  Max Wintermark,et al.  Rapid 3D dynamic arterial spin labeling with a sparse model-based image reconstruction , 2015, NeuroImage.

[4]  Thomas W Okell,et al.  Combined angiography and perfusion using radial imaging and arterial spin labeling , 2018, Magnetic resonance in medicine.

[5]  Sungheon Kim,et al.  Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI , 2014, Magnetic resonance in medicine.

[6]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[7]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[8]  Peter Boesiger,et al.  Array compression for MRI with large coil arrays , 2007, Magnetic resonance in medicine.

[9]  Patrick A Turski,et al.  Noncontrast‐enhanced three‐dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition , 2013, Magnetic resonance in medicine.

[10]  Jian Zhang,et al.  Improved total variation based image compressive sensing recovery by nonlocal regularization , 2012, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013).

[11]  Marc Teboulle,et al.  A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems , 2009, SIAM J. Imaging Sci..

[12]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.

[13]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[14]  D. O. Walsh,et al.  Adaptive reconstruction of phased array MR imagery , 2000, Magnetic resonance in medicine.

[15]  Karla L Miller,et al.  Optimization of 4D vessel‐selective arterial spin labeling angiography using balanced steady‐state free precession and vessel‐encoding , 2016, NMR in biomedicine.

[16]  David G Norris,et al.  Superselective pseudocontinuous arterial spin labeling , 2010, Magnetic resonance in medicine.

[17]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[18]  Peng Hu,et al.  Accelerated noncontrast‐enhanced 4‐dimensional intracranial MR angiography using golden‐angle stack‐of‐stars trajectory and compressed sensing with magnitude subtraction , 2018, Magnetic resonance in medicine.

[19]  T. Grobner Gadolinium--a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[20]  David F Kallmes,et al.  Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. , 2007, Radiology.

[21]  Daisuke Takenaka,et al.  High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. , 2014, Radiology.

[22]  Emanuel Kanal,et al.  Gadolinium based contrast agents (GBCA): Safety overview after 3 decades of clinical experience. , 2016, Magnetic resonance imaging.

[23]  Peter Jezzard,et al.  A kinetic model for vessel‐encoded dynamic angiography with arterial spin labeling , 2012, Magnetic resonance in medicine.

[24]  Hans-Christian Koennecke,et al.  Dynamic spin labeling angiography in extracranial carotid artery stenosis. , 2005, AJNR. American journal of neuroradiology.

[25]  Weiying Dai,et al.  Modified pulsed continuous arterial spin labeling for labeling of a single artery , 2010, Magnetic resonance in medicine.

[26]  Mayank Goyal,et al.  Collateral Circulation in Ischemic Stroke Assessment Tools and Therapeutic Strategies , 2022 .

[27]  Peter Jezzard,et al.  An Optimized Encoding Scheme for Planning Vessel‐Encoded Pseudocontinuous Arterial Spin Labeling , 2015, Magnetic resonance in medicine.

[28]  Eric C Wong,et al.  Vessel‐encoded arterial spin‐labeling using pseudocontinuous tagging , 2007, Magnetic resonance in medicine.

[29]  Arturo Brunetti,et al.  Gadolinium retention in the body: what we know and what we can do , 2017, La radiologia medica.

[30]  Charles H Cunningham,et al.  Temporal stability of adaptive 3D radial MRI using multidimensional golden means , 2009, Magnetic resonance in medicine.

[31]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[32]  Michael Lustig,et al.  k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity , 2006 .

[33]  Toshiyuki Tanaka,et al.  Optimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception? , 2016, PloS one.

[34]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.