Novel dual-probes atomic force microscope for line width measurements

Dual-probe Atomic Force Microscope (AFM) can effectively eliminate the influence of the probe size on measurement of the line width, and realize true three-dimensional measurement. Novel dual-probe AFM consists of probe system, scanning system, alignment system and displacement measurement system. As displacement measurement system, the interferometers are added to the novel dual-probes AFM. In order to simplify the dual-probe AFM structure, self-sensing tuning fork probe is used. Measurement method has two steps: the first step is to align two probes and obtain the reference point; the second step is to scan two sides of measured line by two probes separately, and calculate the line width value according to the reference point. In the alignment of two probes, the alignment method is improved by using the edge alignment and the feedback scanning alignment.

[1]  S. Solares Characterization of deep nanoscale surface trenches with AFM using thin carbon nanotube probes in amplitude-modulation and frequency-force-modulation modes , 2007 .

[2]  David L. Wilson,et al.  Morphological restoration of atomic force microscopy images , 1995 .

[3]  J. Villarrubia Morphological estimation of tip geometry for scanned probe microscopy , 1994 .

[4]  Yueming Hua,et al.  New 3-Dimensional AFM for CD Measurement and Sidewall Characterization , 2011 .

[5]  Ndubuisi G. Orji,et al.  Higher order tip effects in traceable CD-AFM-based linewidth measurements , 2007 .

[6]  X. Xing,et al.  Effective lateral stiffness enhancement of high-aspect-ratio carbon nanotube probe , 2013 .

[7]  H. Dai,et al.  Nanotubes as nanoprobes in scanning probe microscopy , 1996, Nature.

[8]  Richard A. Allen,et al.  Traceable calibration of critical-dimension atomic force microscope linewidth measurements with nanometer uncertainty , 2005 .

[9]  J. Villarrubia Algorithms for Scanned Probe Microscope Image Simulation, Surface Reconstruction, and Tip Estimation , 1997, Journal of research of the National Institute of Standards and Technology.

[10]  David L. Wilson,et al.  Morphological modeling of atomic force microscopy imaging including nanostructure probes and fibrinogen molecules , 1996 .

[11]  Yueming Hua,et al.  Three-dimensional imaging of undercut and sidewall structures by atomic force microscopy. , 2011, The Review of scientific instruments.

[12]  J. Villarrubia Scanned probe microscope tip characterization without calibrated tip characterizers , 1996 .

[13]  M. Esashi,et al.  Resonance enhancement of micromachined resonators with strong mechanical-coupling between two degrees of freedom , 2003 .

[14]  C. Odin,et al.  Tip's finite size effects on atomic force microscopy in the contact mode: simple geometrical considerations for rapid estimation of apex radius and tip angle based on the study of polystyrene latex balls , 1994 .

[15]  Charles M. Lieber,et al.  Structural and functional imaging with carbon nanotube AFM probes. , 2001, Progress in biophysics and molecular biology.

[16]  P. Hansma,et al.  Atomic force microscopy , 1990, Nature.

[17]  Gaoliang Dai,et al.  Atomic force probe for sidewall scanning of nano- and microstructures , 2006 .

[18]  N. F. de Rooij,et al.  Self-Sensing and -Actuating Probe Based on Quartz Tuning Fork Combined with Microfabrication Cantilever for Dynamic Mode Atomic Force Microscopy , 2003 .

[19]  Ronald G. Dixson,et al.  Reference metrology using a next-generation CD-AFM , 2004, SPIE Advanced Lithography.

[20]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[21]  C. L. Cheung,et al.  Structural biology with carbon nanotube AFM probes. , 2000, Chemistry & biology.