Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients.

PURPOSE Kilovoltage cone-beam CT (CBCT) implemented on board a medical accelerator is available for image-guidance applications in our clinic. The objective of this work was to assess the magnitude and stability of the residual setup error associated with CBCT online-guided prostate cancer patient setup. Residual error pertains to the uncertainty in image registration, the limited mechanical accuracy, and the intrafraction motion during imaging and treatment. METHODS AND MATERIALS The residual error for CBCT online-guided correction was first determined in a phantom study. After online correction, the phantom residual error was determined by comparing megavoltage portal images acquired every 90 degrees to the corresponding digitally reconstructed radiographs. In the clinical study, 8 prostate cancer patients were implanted with three radiopaque markers made of high-winding coils. After positioning the patient using the skin marks, a CBCT scan was acquired and the setup error determined by fusing the coils on the CBCT and planning CT scans. The patient setup was then corrected by moving the couch accordingly. A second CBCT scan was acquired immediately after the correction to evaluate the residual target setup error. Intrafraction motion was evaluated by tracking the coils and the bony landmarks on kilovoltage radiographs acquired every 30 s between the two CBCT scans. Corrections based on soft-tissue registration were evaluated offline by aligning the prostate contours defined on both planning CT and CBCT images. RESULTS For ideal rigid phantoms, CBCT image-guided treatment can usually achieve setup accuracy of 1 mm or better. For the patients, after CBCT correction, the target setup error was reduced in almost all cases and was generally within +/-1.5 mm. The image guidance process took 23-35 min, dictated by the computer speed and network configuration. The contribution of the intrafraction motion to the residual setup error was small, with a standard deviation of +/-0.9 mm. The average difference between the setup corrections obtained with coil and soft-tissue registration was greatest in the superoinferior direction and was equal to -1.1 +/- 2.9 mm. CONCLUSION On the basis of the residual setup error measurements, the margin required after online CBCT correction for the patients enrolled in this study would be approximatively 3 mm and is considered to be a lower limit owing to the small intrafraction motion observed. The discrepancy between setup corrections derived from registration using coils or soft tissue can be due in part to the lack of complete three-dimensional information with the coils or to the difficulty in prostate delineation and requires further study.

[1]  Shinichi Shimizu,et al.  Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[3]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[4]  K Lam,et al.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers. , 1995, International journal of radiation oncology, biology, physics.

[5]  H Shirato,et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.

[6]  Gary A Ezzell,et al.  Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[7]  Jean-François Aubry,et al.  Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. , 2004, International journal of radiation oncology, biology, physics.

[8]  R Fahrig,et al.  Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities. , 2000, Medical physics.

[9]  J M Balter,et al.  A comparison of ventilatory prostate movement in four treatment positions. , 2000, International journal of radiation oncology, biology, physics.

[10]  Benjamin Movsas,et al.  Measurement of intrafractional prostate motion using magnetic resonance imaging. , 2002, International journal of radiation oncology, biology, physics.

[11]  David Jaffray,et al.  First clinical experience with cone-beam CT guided radiation therapy; evaluation of dose and geometric accuracy , 2004 .

[12]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[13]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[14]  Jan J W Lagendijk,et al.  Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[16]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[17]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[18]  T. Rockwell Mackie,et al.  Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy , 2002, Technology in cancer research & treatment.

[19]  T E Schultheiss,et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[20]  D. Jaffray,et al.  Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). , 2000, Medical physics.

[21]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[22]  T R Willoughby,et al.  Short-course intensity-modulated radiotherapy for localized prostate cancer with daily transabdominal ultrasound localization of the prostate gland. , 2000, International journal of radiation oncology, biology, physics.

[23]  M. Oldham,et al.  Cone-beam-CT guided radiation therapy: technical implementation. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  J Wong,et al.  Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[25]  Chris Mitchell,et al.  Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer. , 2002, International Journal of Radiation Oncology, Biology, Physics.

[26]  G. Gustafson,et al.  Matched-pair analysis of conformal high-dose-rate brachytherapy boost versus external-beam radiation therapy alone for locally advanced prostate cancer. , 2000, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[27]  G Morton,et al.  Target position variability throughout prostate radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[28]  K L Lam,et al.  Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.

[29]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[30]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[31]  J. Corman,et al.  Intrafractional stability of the prostate using a stereotactic radiotherapy technique , 2003 .

[32]  T R Mackie,et al.  Design of adaptive treatment margins for non-negligible measurement uncertainty: application to ultrasound-guided prostate radiation therapy. , 2004, Physics in medicine and biology.

[33]  Lei Dong,et al.  Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins. , 2003, International journal of radiation oncology, biology, physics.

[34]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[35]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[36]  J Pouliot,et al.  Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. , 1997, International journal of radiation oncology, biology, physics.

[37]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[38]  L. Eapen,et al.  Treatment planning aids in prostate cancer: friend or foe? , 2001, International journal of radiation oncology, biology, physics.

[39]  G. Tsumatori,et al.  Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients , 1998, Cancer.

[40]  Koichi Yamazaki,et al.  Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. , 2003, International journal of radiation oncology, biology, physics.