An implantable optical blood pressure sensor based on pulse transit time

An implantable sensor system for long-term monitoring of blood pressure is realized by taking advantage of the correlation between pulse transit time and blood pressure. The highly integrated implantable sensor module, fabricated using MEMS technologies, uses 8 light emitting diodes (LEDs) and a photodetector on chip level. The sensor is applied to large blood vessels, such as the carotid or femoral arteries, and allows extravascular measurement of highly-resolved photoplethysmograms. In addition, spectrophotometric approaches allow measurement of hemoglobin derivatives. For the calibration of blood pressure measurements, the sensor system has been successfully implemented in animal models.

[1]  J Schüttler,et al.  Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. , 2010, British journal of anaesthesia.

[2]  D. Donoho,et al.  Translation-Invariant De-Noising , 1995 .

[3]  P. Obrist,et al.  Pulse transit time: relationship to blood pressure and myocardial performance. , 1979, Psychophysiology.

[4]  J G THOMAS A method for continuously indicating blood pressure. , 1955, The Journal of physiology.

[5]  Claudia Heilmann,et al.  Implantable sensor for blood pressure determination via pulse transit time , 2010, 2010 IEEE Sensors.

[6]  Gunda Stöber What's new at Biomedizinische Technik/Biomedical Engineering? , 2010 .

[7]  H. Asada,et al.  Utility of the Photoplethysmogram in Circulatory Monitoring , 2008, Anesthesiology.

[8]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[9]  A. Steptoe,et al.  Pulse wave velocity as a measure of blood pressure change. , 1976, Psychophysiology.

[10]  Per Ask,et al.  Pulse wave transit time for monitoring respiration rate , 2006, Medical and Biological Engineering and Computing.

[11]  R W Barnes,et al.  Ultrasonic Measurement of the Elastic Modulus of the Common Carotid Artery The Atherosclerosis Risk in Communities ( ARIC ) Study , 2005 .

[12]  A Steptoe,et al.  Pulse wave velocity and blood pressure change: calibration and applications. , 1976, Psychophysiology.

[13]  J. Schmidli,et al.  Management of uncontrollable hypertension with a carotid sinus stimulation device. , 2007, Hypertension.

[14]  Hans Zappe,et al.  Implantable optical sensor for continuous monitoring of various hemoglobin derivatives and tissue perfusion , 2009, 2009 IEEE Sensors.

[15]  D. Altman,et al.  Comparing methods of measurement: why plotting difference against standard method is misleading , 1995, The Lancet.

[16]  Anton Vonk-Noordegraaf,et al.  Stroke volume response during exercise measured by acetylene uptake and MRI , 2007, Physiological measurement.

[17]  Nan-Chyuan Tsai,et al.  Review of MEMS-based drug delivery and dosing systems , 2007 .

[18]  David L. Donoho,et al.  De-noising by soft-thresholding , 1995, IEEE Trans. Inf. Theory.

[19]  N. Katayama,et al.  Investigation of the time delay between variations in heart rate and blood pressure , 2006, Medical & Biological Engineering & Computing.

[20]  P. Wach,et al.  Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops , 2006, Comput. Biol. Medicine.

[21]  J. Stradling,et al.  Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. , 1995, The European respiratory journal.

[22]  S. Barker,et al.  The measurement of dyshemoglobins and total hemoglobin by pulse oximetry , 2008, Current opinion in anaesthesiology.

[23]  Joseph A Potkay,et al.  Long term, implantable blood pressure monitoring systems , 2008, Biomedical microdevices.

[24]  W. Nichols,et al.  Comprar Mcdonald's blood flow in arteries. Theoretical, experimental and clinical principles | W. Nichols | 9780340985014 | Hodder Education , 2011 .

[25]  Kiyoshi Kotani,et al.  Postural-induced phase shift of respiratory sinus arrhythmia and blood pressure variations: insight from respiratory-phase domain analysis. , 2008, American journal of physiology. Heart and circulatory physiology.

[26]  M. Masè,et al.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure. , 2011, Journal of electrocardiology.

[27]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[28]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[29]  Jeffrey S. Morris,et al.  Improved peak detection and quantification of mass spectrometry data acquired from surface‐enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform , 2005, Proteomics.

[30]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[31]  S. Eckert,et al.  [Validation of continuous blood pressure measurements by pulse transit time: a comparison with invasive measurements in a cardiac intensive care unit]. , 2010, Deutsche medizinische Wochenschrift.

[32]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[33]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[34]  Eric Boerwinkle,et al.  The Atherosclerosis Risk in Communities (ARIC) Study , 2011 .

[35]  A method for continuously indicating blood pressure. , 1955 .

[36]  K. Reynolds,et al.  Global burden of hypertension: analysis of worldwide data , 2005, The Lancet.

[37]  A. Malliani,et al.  Continuous 24-hour assessment of the neural regulation of systemic arterial pressure and RR variabilities in ambulant subjects. , 1990, Circulation.

[38]  A. Murray,et al.  Relation between heart rate and pulse transit time during paced respiration , 2001, Physiological measurement.