All-Inside Meniscal Repair Devices Compared With Their Matched Inside-Out Vertical Mattress Suture Repair

Background: All-inside arthroscopic meniscal repairs are favored by most clinicians because of their lower complication rate and decreased morbidity compared with inside-out techniques. Until now, only 1000 cycles have been used for biomechanical testing. Hypothesis: All-inside meniscal repairs will show inferior biomechanical response to cyclic loading (up to 100,000 cycles) and load-to-failure testing compared with inside-out suture controls. Study Design: Controlled laboratory study. Methods: Bucket-handle tears in 72 porcine menisci were repaired using the Omnispan and Fast-Fix 360 (all-inside devices) and Orthocord 2-0 and Ultrabraid 2-0 sutures (matched controls). Initial displacement, displacement after cyclic loading (100, 500, 1000, 2000, 5000, 10,000, and 100,000 cycles) between 5 and 20 N, ultimate load to failure, and mode of failure were recorded, as well as stiffness. Results: Initial displacement and displacement after cyclic loading were not different between the groups. The Omnispan repair demonstrated the highest load-to-failure force (mean ± SD, 151.3 ± 21.5 N) and was significantly stronger than all the other constructs (Orthocord 2-0, 105.5 ± 20.4 N; Ultrabraid 2-0, 93.4 ± 22.5 N; Fast-Fix 360, 76.6 ± 14.2 N) (P < .0001 for all). The Orthocord vertical inside-out mattress repair was significantly stronger than the Fast-Fix 360 repair (P = .003). The Omnispan (30.8 ± 3.5 N/mm) showed significantly higher stiffness compared with the Ultrabraid 2-0 (22.9 ± 6.9 N/mm, P < .0001) and Fast-Fix 360 (23.7 ± 3.9 N/mm, P = .001). The predominant mode of failure was suture failure. Conclusion: All-inside meniscal devices show comparable biomechanical properties compared with inside-out suture repair in cyclic loading, even after 100,000 cycles. Clinical Relevance: Eight to 10 weeks of rehabilitation might not pose a problem for all repairs in this worst-case scenario.

[1]  Joseph P DeAngelis,et al.  A Biomechanical Evaluation of All-Inside 2-Stitch Meniscal Repair Devices With Matched Inside-Out Suture Repair , 2014, The American journal of sports medicine.

[2]  Daniel M. Buckland,et al.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures? , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  R. LaPrade,et al.  The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair. , 2013, The Knee.

[4]  Jinzhong Zhao,et al.  A meta-analysis comparing meniscal repair with meniscectomy in the treatment of meniscal tears: the more meniscus, the better outcome? , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[5]  M. Herbert,et al.  Biomechanical testing of suture-based meniscal repair devices containing ultrahigh-molecular-weight polyethylene suture: update 2011. , 2012, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[6]  S. R. Golish,et al.  Complications in Brief: Meniscus Repair , 2012, Clinical orthopaedics and related research.

[7]  A. Bedi,et al.  Comparison of Inside-Out and All-Inside Techniques for the Repair of Isolated Meniscal Tears , 2012, The American journal of sports medicine.

[8]  Joseph P DeAngelis,et al.  Comparison of All-Inside Meniscal Repair Devices With Matched Inside-Out Suture Repair , 2011, The American journal of sports medicine.

[9]  R. Brophy,et al.  Meniscal repair versus partial meniscectomy: a systematic review comparing reoperation rates and clinical outcomes. , 2011, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[10]  M. Herbert,et al.  Biomechanical analysis of pullout strengths of rotator cuff and glenoid anchors: 2011 update. , 2011, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[11]  J. Victor,et al.  Long-term outcome after meniscal repair , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[12]  Dae-Hee Lee,et al.  Unfavorable results of partial meniscectomy for complete posterior medial meniscus root tear with early osteoarthritis: a 5- to 8-year follow-up study. , 2010, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[13]  D. Flanigan,et al.  Mechanical comparison of meniscal repair devices with mattress suture devices in vitro , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[14]  Barber Fa Chondral Injury After Meniscal Repair With RapidLoc , 2010, The journal of knee surgery.

[15]  M. Terry,et al.  Cyclic Testing of 3 All-Inside Meniscal Repair Devices , 2009, The American journal of sports medicine.

[16]  M. Herbert,et al.  Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[17]  W. Petersen,et al.  Meniscal repair. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[18]  Greet Cardon,et al.  Pedometer-Determined Physical Activity and Its Comparison With the International Physical Activity Questionnaire in a Sample of Belgian Adults , 2007, Research quarterly for exercise and sport.

[19]  S. Kerner,et al.  Root coverage assessment: validity and reproducibility of an image analysis system. , 2007, Journal of clinical periodontology.

[20]  Terence Dwyer,et al.  Practical Considerations When Using Pedometers to Assess Physical Activity in Population Studies , 2007, Research quarterly for exercise and sport.

[21]  G. Gaesser,et al.  NIH ImageJ and Slice‐O‐Matic Computed Tomography Imaging Software to Quantify Soft Tissue , 2007, Obesity.

[22]  R. von Versen,et al.  Distraction Forces on Repaired Bucket-Handle Lesions in the Medial Meniscus , 2006, The American journal of sports medicine.

[23]  J. Nyland,et al.  Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques , 2006, Knee Surgery, Sports Traumatology, Arthroscopy.

[24]  Billie Giles-Corti,et al.  Demographic and individual correlates of achieving 10,000 steps/day: use of pedometers in a population-based study. , 2006, Health promotion journal of Australia : official journal of Australian Association of Health Promotion Professionals.

[25]  M. Herbert,et al.  Compressive loads in longitudinal lateral meniscus tears: a biomechanical study in porcine knees. , 2005, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[26]  V. Musahl,et al.  Cyclic Testing of Flexible All-Inside Meniscus Suture Anchors: Biomechanical Analysis , 2005 .

[27]  J. Kelly,et al.  Chondral injury and synovitis after arthroscopic meniscal repair using an outside-in mulberry knot suture technique. , 2004, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[28]  A. Bonshahi,et al.  Migration of a broken meniscal arrow: a case report and review of the literature , 2004, Knee Surgery, Sports Traumatology, Arthroscopy.

[29]  R. Siebold,et al.  Clinical evaluation of meniscus repair with a bioabsorbable arrow: a 2- to 3-year follow-up study , 2002, Knee Surgery, Sports Traumatology, Arthroscopy.

[30]  S. Arnoczky,et al.  Tensile Fixation Strengths of Absorbable Meniscal Repair Devices as a Function of Hydrolysis Time , 2001, The American journal of sports medicine.

[31]  Freddie H. Fu,et al.  The Biomechanical Interdependence between the Anterior Cruciate Ligament Replacement Graft and the Medial Meniscus * , 2001, The American journal of sports medicine.

[32]  R. Marx,et al.  Chondral injury following meniscal repair with a biodegradable implant. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[33]  W. Post,et al.  Load to failure of common meniscal repair techniques: effects of suture technique and suture material. , 1997, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[34]  T. Lind,et al.  Failure strength of a new meniscus arrow repair technique: biomechanical comparison with horizontal suture. , 1997, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[35]  G. Barrett,et al.  The effect of suture type on meniscus repair. A clinical analysis. , 1997, The American journal of knee surgery.

[36]  Y Schutz,et al.  Physical activity assessment using a pedometer and its comparison with a questionnaire in a large population survey. , 1995, American journal of epidemiology.

[37]  S. Woo,et al.  Interspecies variation of compressive biomechanical properties of the meniscus. , 1995, Journal of biomedical materials research.

[38]  C. Morgan,et al.  The "all-inside" meniscus repair. , 1991, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[39]  C. E. Henning,et al.  Knee joint surface changes. Long-term follow-up meniscus tear treatment in stable anterior cruciate ligament reconstructions. , 1983, Clinical orthopaedics and related research.